Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/13913
Full metadata record
DC FieldValueLanguage
dc.contributor.authorHussein, ELtegani Ibrahim
dc.contributor.authorSupervisor,- Fargoon Mohammed Ahmed
dc.date.accessioned2016-08-16T11:23:05Z
dc.date.available2016-08-16T11:23:05Z
dc.date.issued2016-05-10
dc.identifier.citationHussein, ELtegani Ibrahim . Dialysis Dose Efficiency with and without on-line clearance monitoring for the Machine (4008S) / ELtegani Ibrahim Hussein ; Fargoon Mohammed Ahmed .- khartoum : Sudan University of Scie nce and Technology , College of engineering , 2016 .-50p. :ill. ;28cm .-M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/13913
dc.descriptionThesisen_US
dc.description.abstractMonitoring of efficiency of heamodialysis treatment is future work, today many companies of heamodialysis machine have been developed applications to calculate the efficiency of dialysis dose using single pool (sp kt/v). In this thesis online clearance monitoring (OCM) were used to monitor the dialysis dose. It used conductivity cell in input of dialysate and output of dialysate to monitor the concentration of dialysate. Monitoring of dialysate conductivity in the spent dialysate stream has been considered as urea monitoring ionic dialysate has been found to be highly correlated to urea clearance. In this study the (OCM) is implemented with ten patients have been treated by heamodialysis in the center of dialysis. Good results for efficiency of dialysis dose were achieved. The study concludes that the online clearance monitoring (OCM) is helpful in many as documentation, decrease the cost of investigation, monitor the adequacy of analysis in every session and assisting the patient treatment management. The study recommends for comparative studies between the online clearance monitoring (OCM) and Diascan for Gambaro Company application.en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectBiomedical Engineeringen_US
dc.subjectMachine 4008Sen_US
dc.subjectwithout on-line clearanceen_US
dc.titleDialysis Dose Efficiency with and without on-line clearance monitoring for the Machine (4008S)en_US
dc.title.alternativeكفاءة جرعة الغسيل الدموي بمراقبة الغسيل المباشر او بدونه لماكينة(4008S)en_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Engineering

Files in This Item:
File Description SizeFormat 
Dialysis Dose Efficiency ....pdfTitle117.51 kBAdobe PDFView/Open
Abstract.pdfAbstract260.27 kBAdobe PDFView/Open
Research.pdfResearch1.7 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.