dc.identifier.citation Alhaj,Mamdouh Balla Edris.Evaluation and Control of Evaporation Losses fromGasoline Internal Floating Roof Tanks/Mamdouh Balla Edris Alhaj,Mohmmed Babekir Alamen Alzubair, Wail Mohammed Alzain A.Gadir; Sumya Abdelmoneim‬‬.-Khartoum: Sudan University of Science and Technology ,College of Petroleum Engineering and Technology,2014.-88P. : ill. ; 28Cm.-B.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/9462
dc.description B.Sc. en_US
dc.description.abstract Gasoline is a Volatile Organic Compounds (VOCs) with different boiling point range of (30-200) ºC. The lightcompounds that have boiling point of less than 40 ºC constitute about 10V %. The objective of this study is to evaluate the amount of evaporation loss of gasoline frominternal floating roof storage tank. The case study is based on U.S Environmental Protection Agency Data (USEPA) the evaporation loss calculation is accomplished by company (A). By comparing the different rim seal system liquid it was found that liquid mounted seal with rim mounted secondary has minimum evaporation loss (4068.19 Ib/yr ) ,which equals toless than (50%) of vapor mounted seal primary only (8679 Ib/yr),so it is most suitable for internal floating roof tanks. Reduction of evaporation loss of gasoline will give attractive economic returns aswell as reducing air pollution and hazards. This reduction could be achieved byplantation of the depots and increase the shadow area around tanks, and reducethe wind speed which would be considered as metrological conditions control action. in addition to the future tank design consideration and mechanicalupgrades for the existing one. en_US
dc.description.sponsorship Sudan University of Science and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Transportation and Refining Engineering en_US
dc.subject Internal Floating Roof Tanks en_US
dc.subject Deck Fitting Loss en_US
dc.subject Deck seam Loss en_US
dc.subject Gasoline en_US
dc.subject Rim Seal Loss en_US
dc.subject Wthdrawal en_US
dc.subject Evaporation Loss en_US
dc.title Evaluation and Control of Evaporation Losses fromGasoline Internal Floating Roof Tanks en_US