SUST Repository

Measurement &Evaluation of Scattered Laser beam and Reflectivity of Some Surfaces as a Means of Laser Safety

Show simple item record

dc.contributor.author FARAH, ATIFA BUSHRA MOHAMED
dc.contributor.author Supervisor, - WAFA SALIH ABD EL-RAHAMAN
dc.date.accessioned 2013-12-25T06:32:21Z
dc.date.available 2013-12-25T06:32:21Z
dc.date.issued 2009-02-02
dc.identifier.citation FARAH , ATIFA BUSHRA MOHAMED . Measurement &Evaluation of Scattered Laser beam and Reflectivity of Some Surfaces as a Means of Laser Safety / ATIFA BUSHRA MOHAMED FARAH ; WAFA SALIH ABD EL-RAHAMAN .- Khartoum : sudan university of scince and technology , Institute of Laser , 2009 .- 83 P. : ill. ; 28cm .- M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/2902
dc.description Thesis en_US
dc.description.abstract Abstract In this study linear and angular scattered intensity of different samples were measured also the reflectivity of samples as a mean of safety was determined. Samples were chosen according to the, availability and uses in laser clinics and laboratories. Samples under study were Aluminum with different coatings, glass, and ceramic. Two types of lasers were used as a source of irradiation; He-Ne laser (λ = 632.8nm, P = 1mW), Diode laser (λ = 808nm, P = 500mW). The detection systems used were: photomultiplier for the former and I.R detector for the later. The reflectivity of samples was determined for different materials at different incident angle (10°, 20°, 30°) The values of linear scattered intensity was measured at scattering angle (10°), and the distance between detector and samples had been changed, this shows inverse relation due to the interaction of the scattered beam with air molecules. In angular scattering the measurement was achieved using a chamber in two situations, before and after covering the chamber. The internal reflection increases the scattered intensity values, and covering of chamber by isolated material that eliminates the internal reflections. In all samples the result of angular scatter shows a dependence of the scattering angle at a fixed incident angle. Al(2) shows higher values of scattered intensity compared with other samples because it’s a polish surface, that means use of this sample in clinics and laboratories may be hazardous. Also the reflectivity (R) was measured for all samples; reflectivity of aluminum samples is high compare with glass and ceramic. iv ‫‪Peak values of scattering intensity were obtained when the incidence and‬‬ ‫.‪reflectance angle are equal‬‬ ‫‪The reflectivity of all samples varied with the incident angle the high value in‬‬ ‫. )2(‪Al‬‬ en_US
dc.description.sponsorship Sudan University Of science Of Technology en_US
dc.language.iso en en_US
dc.publisher sudan university of scince and technology en_US
dc.subject He-Ne laser en_US
dc.subject Diode laser en_US
dc.subject Temporal Coherence en_US
dc.subject Spatial Coherence en_US
dc.subject Chemical Lasers en_US
dc.subject Laser Hazards en_US
dc.subject Reflection en_US
dc.subject Scattering en_US
dc.title Measurement &Evaluation of Scattered Laser beam and Reflectivity of Some Surfaces as a Means of Laser Safety en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Share

Search SUST


Browse

My Account