dc.contributor.author |
Bashir, Sayda Abd Elmarouf Elmahi |
|
dc.contributor.author |
Supervisor, -Alhadi Moheildin Awooda |
|
dc.contributor.author |
Co- Supervisor, -Ali Abdel-Rahman SaeedMarouf |
|
dc.date.accessioned |
2022-10-20T11:43:51Z |
|
dc.date.available |
2022-10-20T11:43:51Z |
|
dc.date.issued |
2022-03-18 |
|
dc.identifier.citation |
Bashir, Sayda Abd Elmarouf Elmahi .Effectiveness of Diode Laser (810nm and 980 nm) in Treatment of Dentine Hypersensitivity \ Sayda Abd Elmarouf Elmahi Bashir ; Alhadi Moheildin Awooda .- Khartoum : sudan university of science and technology , Institute Of Laser , 2022.- 44 P. : ill. ; 28cm .- Higher Diploma |
en_US |
dc.identifier.uri |
http://repository.sustech.edu/handle/123456789/27708 |
|
dc.description |
Higher Diploma |
en_US |
dc.description.abstract |
The successful treatment of dentine hypersensitivity was challenge due to
difficult control of the causative factors. Treatment through conventional
methods (using desensitizing agent} were not effective in all patients. Laser
therapy was introduced as new treatment modality for dentine
hypersensitivity.
This study aimed to evaluate the effectiveness of diode laser on treatment of
dentine hypersensitivity.
A total of 35 teeth of 3voluntary male and female individuals (age from 30 -
60 years) The patients were all in a good health , and not under any
medications for the last 72 hours preceding the treatment , and were not
subjected to any periodontal surgery in the past 3 months. The severity of pain
was recorded in analogous visual scale. Two different wavelengths (810nm
and 980nm) diode laser was applied to a quadrant in a power 1 watt and 60
seconds exposure time. Comparison between different variables by T test
with the level of significance set at p=0.005.
The results showed that there was significant decrease of sensitivity, a
significance (p<0.05) on both wavelengths especially when 810 nm was used
immediately after exposure.
The diode laser (810 nm and 980 nm) therapy was effective on treating
dentine hypersensitivity. Decreasing wavelength led to decrease sensitivity. |
en_US |
dc.description.sponsorship |
Sudan University of Science and Technology |
en_US |
dc.language.iso |
en |
en_US |
dc.publisher |
Sudan University of Science & Technology |
en_US |
dc.subject |
Laser |
en_US |
dc.subject |
Laser Applications |
en_US |
dc.subject |
Dentistry |
en_US |
dc.subject |
Diode laser(980nm) |
en_US |
dc.subject |
Diode Laser (810nm |
en_US |
dc.subject |
Dentine Hypersensitivity |
en_US |
dc.title |
Effectiveness of Diode Laser (810nm and 980 nm) in Treatment of Dentine Hypersensitivity |
en_US |
dc.title.alternative |
فاعلية ليزر الدايود810 و 980 ونانومتر فى علاج حساسية الأسنان |
en_US |
dc.type |
Thesis |
en_US |