SUST Repository

Refinery Wastewater Treatment: Case Study Khartoum Refinery

Show simple item record

dc.contributor.author Aldwo, Alnaeem Adam Alnaeem
dc.contributor.author Albarashi, Afif Gubran Barashi
dc.contributor.author Ali, Badawi Tariq Badawi
dc.contributor.author Hamad, Mokhtar Hamid Mohammed
dc.contributor.author Almobark, Sharnobi Mohammed Abdallah
dc.contributor.author Supervisor, - Zeinab Abdullah
dc.date.accessioned 2022-09-05T08:57:43Z
dc.date.available 2022-09-05T08:57:43Z
dc.date.issued 2022-02-01
dc.identifier.citation Aldwo, Alnaeem Adam Alnaeem.Refinery Wastewater Treatment: Case Study Khartoum Refinery\Alnaeem Adam Alnaeem Aldwo...{etal};Zeinab Abdullah.Khartoum:Sudan University of Science & Technology,College of Petroleum Engineering & Technology,2022.-61p.:ill.;28cm.-Bachelors Search. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/27485
dc.description Thesis en_US
dc.description.abstract The aim of this research is to study how to treat the wastewater and sour water resulting from a petroleum refinery and to determine the characteristics of generated after treatment. The research identified the sources of wastewater pollutants, suitable treatment technologies, and its effect on the environment. Liquid waste produced was studied, the unit that used as well as to treat the waste, and the evaluation of the performance of these units. Laboratory tests were conducted to identify the characteristics of wastes in each stage and using hissy to simulate sour stripping unit to achieve high quality of purified water. The analysis carried include: oil content, phenol content, Biochemical Oxygen Demand, Chemical Oxygen Demand, Ammonia - Dissolved Oxygen, Suspended Solid. The results obtained revealed the following: • The oil content can reach more than 20.000mg/l and this is more than The design capacity of the treatment unit but it can be reduced to less Than 10 mg/l after treatment. • The waste water treatment unit works with capacity more than the Designed, so the efficiency of this unit is not enough. • There is a lot of polluting effluent with concentration more than the Allowed (i.e. NH3, pH) • The above indicates some design problem and the study recommended To add additional units to solve the above mentioned problems and Obstacles en_US
dc.description.sponsorship Sudan University of Science & Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science & Technology en_US
dc.subject Wastewater en_US
dc.subject Refiner en_US
dc.title Refinery Wastewater Treatment: Case Study Khartoum Refinery en_US
dc.title.alternative معالجة المياه الملوثه في مصفاة الخرطوم en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Share

Search SUST


Browse

My Account