SUST Repository

Dialysis Dose Efficiency with and without on-line clearance monitoring for the Machine (4008S)

Show simple item record

dc.contributor.author Hussein, ELtegani Ibrahim
dc.contributor.author Supervisor,- Fargoon Mohammed Ahmed
dc.date.accessioned 2016-08-16T11:23:05Z
dc.date.available 2016-08-16T11:23:05Z
dc.date.issued 2016-05-10
dc.identifier.citation Hussein, ELtegani Ibrahim . Dialysis Dose Efficiency with and without on-line clearance monitoring for the Machine (4008S) / ELtegani Ibrahim Hussein ; Fargoon Mohammed Ahmed .- khartoum : Sudan University of Scie nce and Technology , College of engineering , 2016 .-50p. :ill. ;28cm .-M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/13913
dc.description Thesis en_US
dc.description.abstract Monitoring of efficiency of heamodialysis treatment is future work, today many companies of heamodialysis machine have been developed applications to calculate the efficiency of dialysis dose using single pool (sp kt/v). In this thesis online clearance monitoring (OCM) were used to monitor the dialysis dose. It used conductivity cell in input of dialysate and output of dialysate to monitor the concentration of dialysate. Monitoring of dialysate conductivity in the spent dialysate stream has been considered as urea monitoring ionic dialysate has been found to be highly correlated to urea clearance. In this study the (OCM) is implemented with ten patients have been treated by heamodialysis in the center of dialysis. Good results for efficiency of dialysis dose were achieved. The study concludes that the online clearance monitoring (OCM) is helpful in many as documentation, decrease the cost of investigation, monitor the adequacy of analysis in every session and assisting the patient treatment management. The study recommends for comparative studies between the online clearance monitoring (OCM) and Diascan for Gambaro Company application. en_US
dc.description.sponsorship Sudan University of Science and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Biomedical Engineering en_US
dc.subject Machine 4008S en_US
dc.subject without on-line clearance en_US
dc.title Dialysis Dose Efficiency with and without on-line clearance monitoring for the Machine (4008S) en_US