Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/9051
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAbdalsalam, Ola Salahaddin Alfahal
dc.contributor.authorSupervisor - Alaa aldeen Awouda
dc.date.accessioned2014-12-18T08:11:52Z
dc.date.available2014-12-18T08:11:52Z
dc.date.issued2013-01-10
dc.identifier.citationAbdalsalam,Ola Salahaddin Alfahal .Noninvasive Glucose Detection Using Joint Methods of Scattering-Photo-acoustic Spectroscopy/Ola Salahaddin Alfahal Abdalsalam;Alaa aldeen Awouda.-khartoum:Sudan University of Science and Technology,College of Engineering,2013.-60p:ill;28cm.-M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/9051
dc.descriptionthesisen_US
dc.description.abstractDiabetes is a worldwide spreading disease according to the World Health Organization (2009). In order for diabetic patients to adhere a strict diet, exercise and medication; an accurate and reliable ways glucose measurement must be available. The frequent puncturing of skin in the invasive measuring devices may cause an increase in skin permeability; at the same time noninvasive techniques produce a high percentage of error compared to the invasive techniques. A Joint noninvasive technique was proved to reduce the root mean squared error of prediction. In this study two noninvasive techniques were used in the measurements; the scattering spectroscopy technique based on the Raleigh scattering theory and the linear relation between glucose concentration and the scattering angle, and the Photo-Acoustic Spectroscopy technique. The equations relating each of the methods with glucose concentration was derived. The reading of each method was evaluated against a reference invasive device (Omnitest® plus from B|Braun); using the Clarke Error Grid Analysis (EGA) and the Mean Squared Error of prediction (MSE). The Linear equation relating glucose concentration with the scattering angle produced the best measurements among the three with 63.4% of the reading falling into region A, 36.6% into region B and MSE of (525.8). The three measurements were then combined using the measurements of central tendency; the mean, median and mode. The mean results were the best since 68.2% of the result fell into region A, 31.8% into region B and the MSE was reduced to (452.2).en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectBiomedical Engineeringen_US
dc.subjectAn indirect measurementen_US
dc.subjectGlucose concentrationen_US
dc.subjectDispersion optical spectrumen_US
dc.subjectOptical spectrum analysis and voiceen_US
dc.titleNoninvasive Glucose Detection Using Joint Methods of Scattering-Photo-acoustic Spectroscopyen_US
dc.title.alternativeالقياس غير المباشر لتركيز الجلوكوز باستخدام طيف التشتت الضوئي وطيف التحليل الضوئي الصوتيen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Engineering

Files in This Item:
File Description SizeFormat 
Noninvasive Glucose Detection ...pdftitle113.62 kBAdobe PDFView/Open
Contents.pdfContents175.25 kBAdobe PDFView/Open
ABSTRACT.pdfABSTRACT189.64 kBAdobe PDFView/Open
Research.pdf
  Restricted Access
Research56.88 MBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.