dc.identifier.citationMusa,Amir AbuBakr . Study of Pressure drop in Heat Exchangers : A thesis submitted in partial fulfillment of the requirements for the degree of Master of Science in Mechanical Engineering./Amir AbuBakr Musa; William Ibrahim Assad.-khartoum:sudan university of science and technology,College of Engineering,2005.-86p:ill;28cm.-M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/8114
dc.descriptionthesisen_US
dc.description.abstractHeat exchangers are frequently used in industry especially in steam and gas turbines power plants, as air pre-heaters or economizers and the like. These are mainly used to recover part of the thermal energy in exhaust and flue gases. The measure of performance of these equipments is usually given as a heat ratio which is a measure of the heat recovered from the exhaust. Heat exchangers suffer from pressure losses due to the resistance to fluid flow through the passages on both sides of the exchanger. The pressure drop means in most cases, a loss in the useful work output. In this research the investigation concentrates on the thermal ratio and the pressure drop in heat exchangers applied in existing power stations. Three of the largest power stations in Sudan are examined: namely: i.Khartoum Refinery Company ( at Elgili). ii.Khartoum North Thermal Power Station. iii.Kenana Sugar Factory. Temperatures and pressures were measured and calculations were carried out and the results were presented, and discussed. Kern methods for calculating the pressure drop were examined using data obtained from unit (2) phase (I) in Khartoum North thermal power station. The results obtained revealed that: a)The thermal ratio of heat exchangers, in addition to their dependence on the thermal properties of the material from which they are made, was affected by the method of design and the inlet conditions. The results of the tests showed that for the shell and tube type of heat exchanger used in Kenana Sugar Factory, the thermal ratio was 0.52 while it was about 0.777 for the rotary heat exchanger used in Khartoum North thermal power station, phase (II) unit (4). b)The least pressure drop amounting to about (190 pa) i.e. about 1.6% of the inlet pressure, when using bar heaters as in Khartoum Refinery Company, and the highest pressure drop was (1830 pa) i.e. about 7.7% of the inlet pressure drop, when using Rotary heat exchangers, as in phase (II) unit (4) of Khartoum North thermal power station.en_US
dc.description.sponsorshipsudan university of science and technologyen_US
dc.language.isoenen_US
dc.publishersudan university of science and technologyen_US
dc.subjectStudy of Pressureen_US
dc.subjectdrop in Heat Exchangersen_US
dc.subjectMechanical Engineering.en_US
dc.titleStudy of Pressure drop in Heat Exchangersen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Engineering

Files in This Item:
File Description SizeFormat 
Study of Pressure drop ...pdftitle126 kBAdobe PDFView/Open
Chapter one .pdf
  Restricted Access
Chapter 37.72 kBAdobe PDFView/Open Request a copy
Chapter Two.pdf
  Restricted Access
Chapter 1.17 MBAdobe PDFView/Open Request a copy
Chapter Three.pdf
  Restricted Access
Chapter 231.36 kBAdobe PDFView/Open Request a copy
Chapter Four.pdf
  Restricted Access
Chapter 136.56 kBAdobe PDFView/Open Request a copy
Chapter Five.pdf
  Restricted Access
Chapter 31 kBAdobe PDFView/Open Request a copy
References.pdfReferences31.67 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.