Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/6243
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAbdellatef, Nassir Elzubear
dc.contributor.authorSupervisor - Hassan Abdellatif Osman
dc.date.accessioned2014-07-06T10:27:59Z
dc.date.available2014-07-06T10:27:59Z
dc.date.issued2009-07-01
dc.identifier.citationAbdellatef ,Nassir Elzubear .EFFECT OF AMBIENT TEMPERATURE UPON GARRI POWER PLANT COMBINED CYCLE/Nassir Elzubear Abdellatef ;Hassan Abdellatif Osman.-Khartoum:Sudan University of Science and Technology,College of Engineering,2009.-133P. : ill. ; 24Cm.-M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/6243
dc.descriptionThesisen_US
dc.description.abstractThe gas turbine performance is highly sensitive to the Compressor Inlet air temperature. In Sudan the output of gas turbine falls to value that is less than the rated output under high temperature Conditions. The solution of this problem is important because the Peak Demand season in Sudan happens in the summer. As one of the convenient methods of inlet air cooling is evaporative cooling type considered as appropriate for hot and dry climate. The gas turbine and combined plants in Sudan installed in Such ambient conditions, therefore this method can be used to Improve the performance of gas turbine and combined cycle plants to recover the Peak Demand . The main purpose of this research is to investigate, analyze and calculate the effect of inlet air cooling. This method applies efficiently in garii power plant gas turbine. The study results indicate that refrigerated cooling appear as The technically feasible, it can give the maximum benefits of turbine Inlet cooling. While evaporative cooling is economically feasible, it Is passive option that can utilize readily available Nile water without demineralization. The study recommended that the suitable inlet air cooling type For garri Power station is the evaporative cooling system because it is highly efficient in hot and dry area.en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectMECHANICAL ENGINEERINGen_US
dc.subjectAMBIENT TEMPERATUREen_US
dc.subjectGARRI POWER PLANTen_US
dc.subjectThe gas turbineen_US
dc.titleEFFECT OF AMBIENT TEMPERATURE UPON GARRI POWER PLANT COMBINED CYCLEen_US
dc.title.alternativeتأثير درجةِ حرارة الجو على محطةِ كهرباء قري ذات الدورةً المزدوجةen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Engineering

Files in This Item:
File Description SizeFormat 
EFFECT OF AMBIENT TEMPERATURE ....pdftitle182.17 kBAdobe PDFView/Open
Presentation [Compatibility Mode].pdfResearch12.48 MBAdobe PDFView/Open
Abstract.pdfAbstract201.92 kBAdobe PDFView/Open
Research.pdf
  Restricted Access
Research14.2 MBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.