Please use this identifier to cite or link to this item:
https://repository.sustech.edu/handle/123456789/5555| Title: | Effect of Heamolysis on Aspartate Amino Transferase, Potassium and Phosphate Measurement |
| Other Titles: | تأثير إنحلال الدم على قياس الاسبارتيت أمينوترانسفيريز، البوتاسيوم والفوسفات |
| Authors: | Abd elrouf, Mohamed Babiker Supervisor,- Abdelhafiz Hassan Khattab |
| Keywords: | Heamolysis-Aspartate Amino Transferase |
| Issue Date: | 1-Jan-2009 |
| Publisher: | Sudan University of Science and Technology |
| Citation: | Abd elrouf,Mohamed Babiker.Effect of Heamolysis on Aspartate Amino Transferase, Potassium and Phosphate Measurement/Mohamed Babiker Abd elrouf;Abdelhafiz Hassan Khattab.-Khartoum:Sudan University of Science and Technology,college of Medical Laboratory Science,2009.-79p. : ill. ; 28cm.-M.Sc. |
| Abstract: | An experimental study conducted during the period October 2008 to March 2009, in ALNAW hospital and KHARTOUM teaching hospital research and laboratory unite. About twenty different pooled plasma were collected from a 80 apparently healthy volunteers, heamolysate was prepared by freezing at -20 over night, serial dilution of haemolysate was prepared (0.125, 0.25, 0.5, 1, 2, 4, 8 g/dl), each pooled plasma was dispense into different 8 tubes (900μl in each tube) and then added 100 μl from different concentration of heamolysate in each tubes except in compare tube (base line) was added 100 μl of distilled water, and then measure plasma AST, potassium and phosphate in each tubes. Plasma level of AST and phosphate were measured using Hitachi 902 Analyzer. Plasma level of potassium was measured using ion selective electrode. The result showed plasma AST, potassium and phosphate were significantly raised at hemoglobin concentration 0.4 and 0.8 g/dl (P<0.01), whereas plasma potassium and AST was significantly increased at hemoglobin concentration 0.1 and 0.2 g/dl (P<0.01), the plasma potassium only was significantly increased at hemoglobin concentration 0.05 g/dl (P<0.05). |
| Description: | Thesis |
| URI: | http://repository.sustech.edu/handle/123456789/5555 |
| Appears in Collections: | Masters Dissertations : Medical Laboratory Science |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| Effect of Heamolysis ... .pdf | Title | 70.03 kB | Adobe PDF | View/Open |
| Abstract.pdf | Abstract | 112.01 kB | Adobe PDF | View/Open |
| Research.pdf Restricted Access | Research | 320.26 kB | Adobe PDF | View/Open Request a copy |
| Reference.pdf Restricted Access | Reference | 50.46 kB | Adobe PDF | View/Open Request a copy |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.