Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/3718
Title: Evaluation of Radiation Exposure to Patients and Staff During Bone Scan Procedure
Authors: Boshara, Nada Ahmed Alsadeg
Supervisor -Abdelmoneim Adam Mohamed Sulieman
Keywords: Evaluation
Radiation
Issue Date: 1-Feb-2011
Publisher: sudan university of science and technology
Citation: Boshara,Nada Ahmed Alsadeg . Evaluation of Radiation Exposure to Patients and Staff During Bone Scan Procedure/Nada Ahmed Alsadeg ;Abdelmoneim Adam Mohamed Sulieman.- Khartoum : sudan university of science and technology,Medical Radiologic Science ,2012.- 120p. : ill . ;28cm .- M.Sc.
Abstract: Although bone scan is widely used as a frequent screening test; imaging of the skeleton using radioactive substances in Sudan using radio active substance in form of radiopharmaceuticals, standing to our knowledge, there are no studies aimed to evaluate the radiation doses to the staff due to performing these types of procedures; thus this study is consider a bonier in Sudan. The study aimed to evaluate the radiation doses received by the nuclear medicine staff during the whole body bone scan procedure and to estimate the organ doses during the entire procedures. The following study was carried out a 5 mCi of 99mTc-MDP follow intravenous injection and accumulated in bone rapidly. Anterior and posterior data acquisition achieved using MiE single head gamma camera. The study concerned on Three nuclear medicine staff with average 25 year, 77 kg weight, 177 cm height and 0.0024 BMI, positioned TLDs over their right hand and chest. The mean chest and hand doses for the three adult staff were 64.4 mGy, 6.3 mGy respectively. The staff organ doses received by the lung, bone marrow, colon and stomach were of magnitude of 0.77 mSv, and the skin dose is equal 0.032 mSv, hence only 15.4 mSv is received by the staffs' organ what is within the acceptable 50 mSv annual organ dose limit determined by ICRP. It had been observed that, chest doses was higher than hand doses because of direct handling with the injected patient and leaning the patient during submitting to scanning procedure. Increasing of staff and co-patient awareness about radiation safety and wearing lead apron inside any controlled area is recommended to enhance radiation protection in Al-Nilen diagnostic center.
Description: Thesis
URI: http://repository.sustech.edu/handle/123456789/3718
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Chapter five.pdf
  Restricted Access
Chapter 79.61 kBAdobe PDFView/Open Request a copy
Chapter four.pdf
  Restricted Access
Chapter 123.93 kBAdobe PDFView/Open Request a copy
Chapter I.pdf
  Restricted Access
Chapter 108.69 kBAdobe PDFView/Open Request a copy
Chapter II .pdf
  Restricted Access
Chapter 340.9 kBAdobe PDFView/Open Request a copy
chaptre three.pdf
  Restricted Access
Chapter 311.05 kBAdobe PDFView/Open Request a copy
Dedicate.pdfAbstract 89.42 kBAdobe PDFView/Open
Evaluation of Radiation Exposure ... .pdfTitle61.2 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.