Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/22331
Title: Detection of Biliary System Obstruction using Magnetic Resonance Cholangio-Pancreatographyand Ultrasonography
Other Titles: الكشف عن أسباب انسداد الجهاز المراري بواسطةالرنين المغنطيسي والموجات فوق الصوتية
Authors: Gerballah, Amane Ahmed
Supervisor, -Mona Ahmed Mohammed
Keywords: Medical Radiologic Sciences
Diagnostic Radiologic
Biliary System Obstruction
Magnetic Resonance Cholangio-Pancreatographyand
Ultrasonography
Issue Date: 18-Oct-2018
Publisher: Sudan University of Science and Technology
Citation: Gerballah, Amane Ahmed . Detection of Biliary System Obstruction using Magnetic Resonance Cholangio-Pancreatographyand Ultrasonography \ Amane Ahmed Gerballah ; Mona Ahmed Mohammed .- Khartoum : Sudan University of Science and Technology , College of Medical Radiologic Science , 2018 .- 45 p. :ill;28cm.- M.Sc
Abstract: This is prospective study to measure CBD,CHD,GB and cystic duct by U/S and MRCP and to test the accuracy of each modality in diagnosing causes of biliary system obstruction. The study was done in Khartoum state hospitals (Ibnsena-Soba on february2018), 52patients were tested by both U/S and MRCP. Using U/S 3.5MHz prom, TR (1500-200ms), TI (110-150ms), TE (240-300ms), FOV (300mm) and slice sickness 1mm, those examinations were performed using siemens (0.32T) permanent magnetom, Phillips (2.5T) and siemens (1.5T), the examinations were done by U/S using Fukuda, Toshiba and Sheimadzo machines. Ducts were measured by two technologists in each hospital and images diagnosed by two radiologists and two sonologists. measurements were done for CBD, cystic duct and GB, the causes of obstructive jaundice were detected as CBD stones, cystic duct stones, GB stones, GB mass and Ca-head of pancreas. The accuracy test was applied to determine the accuracy of each modality and it found that MRCP is the most accurate in measuring CBD (70.8%) while for U/S is (29.2%) and CA (61.1%), while for U/S is (38.9%), but U/S is most accurate in measuring GB (100%) and cystic duct stone (55.6%), while for MRICP (44.4%). As well as the most effected age group is 31-40 years (76.5%).
Description: Thesis
URI: http://repository.sustech.edu/handle/123456789/22331
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Detection of Biliary ... .pdfResearch1.6 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.