Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/22331
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGerballah, Amane Ahmed-
dc.contributor.authorSupervisor, -Mona Ahmed Mohammed-
dc.date.accessioned2019-02-11T06:47:10Z-
dc.date.available2019-02-11T06:47:10Z-
dc.date.issued2018-10-18-
dc.identifier.citationGerballah, Amane Ahmed . Detection of Biliary System Obstruction using Magnetic Resonance Cholangio-Pancreatographyand Ultrasonography \ Amane Ahmed Gerballah ; Mona Ahmed Mohammed .- Khartoum : Sudan University of Science and Technology , College of Medical Radiologic Science , 2018 .- 45 p. :ill;28cm.- M.Scen_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/22331-
dc.descriptionThesisen_US
dc.description.abstractThis is prospective study to measure CBD,CHD,GB and cystic duct by U/S and MRCP and to test the accuracy of each modality in diagnosing causes of biliary system obstruction. The study was done in Khartoum state hospitals (Ibnsena-Soba on february2018), 52patients were tested by both U/S and MRCP. Using U/S 3.5MHz prom, TR (1500-200ms), TI (110-150ms), TE (240-300ms), FOV (300mm) and slice sickness 1mm, those examinations were performed using siemens (0.32T) permanent magnetom, Phillips (2.5T) and siemens (1.5T), the examinations were done by U/S using Fukuda, Toshiba and Sheimadzo machines. Ducts were measured by two technologists in each hospital and images diagnosed by two radiologists and two sonologists. measurements were done for CBD, cystic duct and GB, the causes of obstructive jaundice were detected as CBD stones, cystic duct stones, GB stones, GB mass and Ca-head of pancreas. The accuracy test was applied to determine the accuracy of each modality and it found that MRCP is the most accurate in measuring CBD (70.8%) while for U/S is (29.2%) and CA (61.1%), while for U/S is (38.9%), but U/S is most accurate in measuring GB (100%) and cystic duct stone (55.6%), while for MRICP (44.4%). As well as the most effected age group is 31-40 years (76.5%).en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectMedical Radiologic Sciencesen_US
dc.subjectDiagnostic Radiologicen_US
dc.subjectBiliary System Obstructionen_US
dc.subjectMagnetic Resonance Cholangio-Pancreatographyanden_US
dc.subjectUltrasonographyen_US
dc.titleDetection of Biliary System Obstruction using Magnetic Resonance Cholangio-Pancreatographyand Ultrasonographyen_US
dc.title.alternativeالكشف عن أسباب انسداد الجهاز المراري بواسطةالرنين المغنطيسي والموجات فوق الصوتيةen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Detection of Biliary ... .pdfResearch1.6 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.