dc.date.issued2016-08-10
dc.identifier.citationAHMED, AHMED MAHJOUB MIRGHANI . Design of a New Oil Cooling Lubricant Closed System for Gas Turbines in Gari (1, 2) Power Station / AHMED MAHJOUB MIRGHANI AHMED ; Ali Mohammed Hamdan Adam .- Khartoum: Sudan University of Science and Technology, college of Engineering,2016 .- 68p. :ill. ;28cm .-M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/14471
dc.descriptionThesisen_US
dc.description.abstractThe cooling lubrication oil of the turbine gas in GARI Thermal Station (1and 2) depends on the passage of the lubricating oil outside the tubes of the heat exchanger, and the cooling water from the cooling towers go to the inside of the pipes in the heat exchanger. It is an open system which makes the control of the treatment of the cooling water difficult. This system suffers from the effectiveness of the cooling because of the layer of lime salts building around the membrane tube, this layers is growing with time, and become as an insulator for heat exchange and cause the increment of the temperature of the lubricating oil, which affects the stability of the production of gas turbine. This research attempted to solve this cooling problem. It was done by examining the user's cooling system, and then changes the system to a new system. The new system is based on a closed system with treated cooling water to cool the lubricating oil. Then the treated water is cooled by the water coming from the cooling towers. This done by adding a flat heat exchanger, which was designed, and then was chosen from among a large number of thermal flat exchangers The lubricating oil entering at 70 ºC and leaves at 49 ºC and cooled by the treated water that enters at 33 ºC and leaves at 43 ºC. While the cooling water from the cooling towers at 31 ºC cooled the treated water and leaves at 32.5 ºC. The effectiveness of the new system was confirmed by using computational fluid dynamics program. The results show the consequences effective heat exchange between the lubricating oil and cooling water and matching the temperature degrees of the design heat exchanger. It was then worked out a model illustrates the new cooling system with full accessories. The cost of the production of the new system is found to be equivalent to the cast of loss of production due to gas turbine cooling system for a period of 9 days and 3 hours.en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectMechanical Engineeringen_US
dc.subjectPOWERen_US
dc.subjectPower Stationen_US
dc.subjectOil Cooling Lubricant Closeden_US
dc.subjectGas Turbines in Garien_US
dc.titleDesign of a New Oil Cooling Lubricant Closed System for Gas Turbines in Gari (1, 2) Power Stationen_US
dc.title.alternativeتصميم نظام تبريد جديد مغلق لزيت تزييت التوربينة الغازية في محطة قري(2, 1)en_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Engineering

Files in This Item:
File Description SizeFormat 
Characteristic Functions of...pdfTitel49.33 kBAdobe PDFView/Open
Abstract.pdfAbstract474.09 kBAdobe PDFView/Open
Research.pdfResearch2.15 MBAdobe PDFView/Open
Appendix.pdfAppinex3.1 MBAdobe PDFView/Open
Appendix 2.pdfAppinex1.43 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.