Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/14289
Title: Structural Behavior of Power Transmission Towers
Other Titles: السلوك الإنشائي لأبراج نقل الطاقة الكهربائية
Authors: Mohammed, Omran Elbashir
Supervisor,- Abusamra Awad Attaelmanan
Keywords: civil engineering
Structural Engineering
The structural behavior
electricity
Issue Date: 10-Mar-2016
Publisher: Sudan University of Science and Technology
Citation: Mohammed, Omran Elbashir . Structural Behavior of Power Transmission Towers / Omran Elbashir Mohammed;Abusamra Awad Attaelmanan .- Khartoum: Sudan University of Science and Technology, college of Engineering, 2016 .- 113p. :ill .;28cm .-M.Sc.
Abstract: This research is concerned with analysis and design of the power transmission towers. Three types of the power transmission towers were considered in this research to investigate their structural behavior. Data have been collected about the types of towers, their usage, and the types of the applied loads. The study concentrated on the 220 kV double circuit’s Wawa- Wadi halfa Transmission Line Project, the three types of the transmission towers has different configurations and same height and conductor tension. SAP 2000 program was used to carry out structural analysis and design of transmission towers under different load cases. The specifications involved were American Standards. Analysis results was used to make a comparison between three types of power transmission towers and to discuss their behavior under different load combination. The results consist of axial forces distribution on leg, displacements, weight due to dead load and elastic buckling. In analysis it was considered 6 buckling modes and was shown significant increment of buckling loads and buckling factors for each transmission tower. The results indicates that displacement increases in direct proportion to height and that the axial force increase in inverse proportion to height, It was shown decrement the buckling load for each transmission tower models by applying dead and lateral load. The structural behavior of the transmission towers varies depending on the change of transmission towers configuration. Finally it was appeared transmission tower (2) was the most efficient configuration of transmission tower model because it was the most economical and lowest in design sections size, weight, member’s density and axial forces distribution on leg.
Description: Thesis
URI: http://repository.sustech.edu/handle/123456789/14289
Appears in Collections:Masters Dissertations : Engineering

Files in This Item:
File Description SizeFormat 
Structural Behavior of... .pdfResearch2.82 MBAdobe PDFView/Open
Appindex.pdfAppinex283.29 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.