Please use this identifier to cite or link to this item:
https://repository.sustech.edu/handle/123456789/8126
Title: | ASSESSMENT OF RADIATION DOSE IN ORTHOPEDIC INTERVENTIONAL PROCEDURES |
Other Titles: | تقييم الجرعات الاشعاعية في فحوصات العظام بالاشعة التداخلية |
Authors: | Hamid, Hamid Osman Supervisor - Adam Khatir Sam |
Keywords: | ORTHOPEDIC RADIATION DOSE |
Issue Date: | 1-Aug-2012 |
Publisher: | Sudan University of Science and Technology |
Citation: | Hamid,Hamid Osman ;ASSESSMENT OF RADIATION DOSE IN ORTHOPEDIC INTERVENTIONAL PROCEDURES/Hamid Osman Hamid;Adam Khatir Sam . -Khartoum : Sudan University of Science And Technology, College of Medical Radiology , 2012.-50 p:Ill:28 cm.- P.h.D |
Abstract: | The main objective of this study is to evaluate the radiation dose incurred by medical staff and patients during orthopedic procedures, namely dynamic hip screw (DHS), dynamic cannulated screw (DCS) and closed intramedullary nailing (IMN). The entrance skin dose (ESD) for both staff and patients at different anatomic locations was measured using lithium fluoride (LiF: Mg, P,Cu GR: 200) thermoluminescence dosimeters (TLDs) and TLD reader (Fimel-France). The ambient dose around C-arm machine was also measured using CONYII ionization chamber. The mean values of fluoroscopic exposure factors for the procedures were 71±7 kVp, 1.3±0.6 mA and 0.68±0.13 min. The mean ESD was 0.26 and 7.9 mGy for staff and patient, respectively. On the average, the ESD for staff at specific anatomic locations was 0.15 ±0.02 (lens), 0.064 ± 0.01 (thyroid), 0.20±0.06 (chest), 0.23±0.2 (right hand) and 0.19±0.04 mGy for the left leg. The results revealed that staff and patients received higher radiation doses during DHS relative to DCS procedures; and that the orthopedist hands were most exposed than other organs. . |
Description: | Thesis |
URI: | http://repository.sustech.edu/handle/123456789/8126 |
Appears in Collections: | PhD theses :Medical Radiologic Science |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
ASSESSMENT OF RADIATION ... .pdf | Title | 44.29 kB | Adobe PDF | View/Open |
Abstract.pdf | Abstract | 96.99 kB | Adobe PDF | View/Open |
Thyroid radiation dose.pdf Restricted Access | Chapter | 315.85 kB | Adobe PDF | View/Open Request a copy |
CHAPTER ONE.pdf Restricted Access | CHAPTER | 432.86 kB | Adobe PDF | View/Open Request a copy |
review article.pdf | CHAPTER | 140.23 kB | Adobe PDF | View/Open |
ambient exposure.pdf | CHAPTER | 135.67 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.