Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/8126
Full metadata record
DC FieldValueLanguage
dc.contributor.authorHamid, Hamid Osman
dc.contributor.authorSupervisor - Adam Khatir Sam
dc.date.accessioned2014-11-19T08:58:03Z
dc.date.available2014-11-19T08:58:03Z
dc.date.issued2012-08-01
dc.identifier.citationHamid,Hamid Osman ;ASSESSMENT OF RADIATION DOSE IN ORTHOPEDIC INTERVENTIONAL PROCEDURES/Hamid Osman Hamid;Adam Khatir Sam . -Khartoum : Sudan University of Science And Technology, College of Medical Radiology , 2012.-50 p:Ill:28 cm.- P.h.Den_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/8126
dc.descriptionThesisen_US
dc.description.abstractThe main objective of this study is to evaluate the radiation dose incurred by medical staff and patients during orthopedic procedures, namely dynamic hip screw (DHS), dynamic cannulated screw (DCS) and closed intramedullary nailing (IMN). The entrance skin dose (ESD) for both staff and patients at different anatomic locations was measured using lithium fluoride (LiF: Mg, P,Cu GR: 200) thermoluminescence dosimeters (TLDs) and TLD reader (Fimel-France). The ambient dose around C-arm machine was also measured using CONYII ionization chamber. The mean values of fluoroscopic exposure factors for the procedures were 71±7 kVp, 1.3±0.6 mA and 0.68±0.13 min. The mean ESD was 0.26 and 7.9 mGy for staff and patient, respectively. On the average, the ESD for staff at specific anatomic locations was 0.15 ±0.02 (lens), 0.064 ± 0.01 (thyroid), 0.20±0.06 (chest), 0.23±0.2 (right hand) and 0.19±0.04 mGy for the left leg. The results revealed that staff and patients received higher radiation doses during DHS relative to DCS procedures; and that the orthopedist hands were most exposed than other organs. .en_US
dc.description.sponsorshipSudan University for Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectORTHOPEDICen_US
dc.subjectRADIATION DOSEen_US
dc.titleASSESSMENT OF RADIATION DOSE IN ORTHOPEDIC INTERVENTIONAL PROCEDURESen_US
dc.title.alternativeتقييم الجرعات الاشعاعية في فحوصات العظام بالاشعة التداخليةen_US
dc.typeThesisen_US
Appears in Collections:PhD theses :Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
ASSESSMENT OF RADIATION ... .pdfTitle44.29 kBAdobe PDFView/Open
Abstract.pdfAbstract96.99 kBAdobe PDFView/Open
Thyroid radiation dose.pdf
  Restricted Access
Chapter315.85 kBAdobe PDFView/Open Request a copy
CHAPTER ONE.pdf
  Restricted Access
CHAPTER 432.86 kBAdobe PDFView/Open Request a copy
review article.pdfCHAPTER140.23 kBAdobe PDFView/Open
ambient exposure.pdfCHAPTER135.67 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.