Title: Minimization of Distribution System Harmonics : Case Study Sudanese Malaysian Steel Factory
Authors: Mustafa, Mustafa Ahmed Dafalla
Supervisor - Eisa Bashier Mohammed
Keywords: Electrical Engineering
Electrical Engineering - Power
Distribution System Harmonics
Power
Issue Date: 1-Jun-2006
Publisher: Sudan University of Science and Technology
Citation: Mustafa, Mustafa Ahmed Dafalla .Minimization of Distribution System Harmonics : Case Study Sudanese Malaysian Steel Factory/ Mustafa Ahmed Dafalla Mustafa;Eisa Bashier Mohammed.-Khartoum:Sudan University of Science and Technology,College of Engineering,2006.-102P. : ill. : 28Cm.-M.Sc.
Abstract: The Harmonics in Distribution Systems come from transformers or saturable reactors, arc furnace, welding machines, florescent lamps, rotating machines and power electronics devices. In general, the non linear loads in which the relationship between the voltage and current is not constant. It is considered that there is no risk of harmful perturbation from 5 to 10%. Above 10%, problems will certainly occur. Equipments can be affected by the harmonics like transformers with increase of losses, risk of overheating, noise and even insulation stress problems. Cables that can heat too much due to as Kelvin effect above 400 Hz. Induction relays and meters that are pertubated by harmonic torques giving incorrect trippings and readings. The solutions that can be used to improve the p.f. and to protect the capacitors are either de-rate the capacitors or using detuning reactors, and also by using harmonic filters. This thesis presents the definitions of harmonics, generation, causes, analysis and solutions due to IEEE 519 standard of harmonics. The basic aim of the study is how to minimize the Harmonics in Distribution Systems and applied the study in Sudanese Malaysian steel factory. It was found that the factory has been suffered from the damage of sensitive electronic control devices, poor power factor and tripping of circuit breaker. By the measuring the power ,current ,voltage ,power factor and the total harmonic distortion with aid of standard formulas and calculation the suitable solution was found that using capacitors with reactors in series for both minimization of harmonics and improving the power factor in the factor.
Description: Thesis
URI: http://repository.sustech.edu/handle/123456789/7994
Appears in Collections:Masters Dissertations : Engineering

Files in This Item:
File Description SizeFormat 
Minimization of Distribution System ...pdftitle64.49 kBAdobe PDFView/Open
Abstract.pdfAbstract193.89 kBAdobe PDFView/Open
Research.pdf
  Restricted Access
Research2.31 MBAdobe PDFView/Open Request a copy
ahmed123 001.jpgappendix176.51 kBJPEGView/Open
ahmed123 002.jpgappendix202.34 kBJPEGView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.