Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/26476
Title: Estimation of Pediatric Patient’s Radiation Dose During Nuclear Medicine Test
Other Titles: تقييم الجرعة الاشعاعية للأطفال المرضى أثناء فحوصات الطب النووي
Authors: Elmakki, Mayada AbazarSuliman
Supervisor, -Mohamed Elfadil Mohamed
Keywords: Medical Radiologic Sciences
Nuclear Medicine Sciences
Pediatric Patient’s Radiation
Issue Date: 12-Mar-2021
Publisher: Sudan University of Science and Technology
Citation: Elmakki, Mayada AbazarSuliman . Estimation of Pediatric Patient’s Radiation Dose During Nuclear Medicine Test \ Mayada AbazarSulimanElmakki ; Mohamed Elfadil Mohamed .- Khartoum:Sudan University of Science & Technology,College of Medical Radiologic Science,2021.-63 p.:ill.;28cm.-M.Sc.
Abstract: Estimate of effective dose for pediatric in Khartoum state for three nuclear medicine scan the thyroid, Kidney (dynamic renal scan with DTPA) and bone using descriptive, analytic and cross sectional method in the research. the average of effective dose to all patients according to their age, for age group from 1-3 years old the mean for thyroid was 1.2 mSv, for dynamic renal scan 0.73 mSv and for bone scan it was 3.45 mSv. For age group 4-8 years old the mean for thyroid was 2.84 mSv, for dynamic renal scan 0.80 mSv and for bone scan it was 3.32 mSv. For age group 9-13 years old the mean for thyroid was 2.22 mSv, for dynamic renal scan 0.82 mSv and for bone scan it was 3.35 mSv. For age group 14-17 years old the mean for thyroid was 1.85 mSv, for dynamic renal scan 0.76 mSv and for bone scan it was 3.45 mSv. And the comparison between present study with other studies according to ED where for thyroid the present study was 2.03 mSv while in ARPANSA 2008 study it was 2.2 mSv which consider higher than our present study. For dynamic renal scan present study was 0.78 mSv while in ARPANSA 2008 study was 6 mSv which consider higher than our present study while in Silvia Maria 2014 study was 0.75 mSv which consider lower than our present study. For bone present study was 3.39 mSv while in ARPANSA 2008 study was 5.5 mSv which consider higher than our present study.
Description: Thesis
URI: http://repository.sustech.edu/handle/123456789/26476
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Estimation of Pediatric ....pdfResearch779.62 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.