Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/26476
Full metadata record
DC FieldValueLanguage
dc.contributor.authorElmakki, Mayada AbazarSuliman-
dc.contributor.authorSupervisor, -Mohamed Elfadil Mohamed-
dc.date.accessioned2021-08-24T07:53:34Z-
dc.date.available2021-08-24T07:53:34Z-
dc.date.issued2021-03-12-
dc.identifier.citationElmakki, Mayada AbazarSuliman . Estimation of Pediatric Patient’s Radiation Dose During Nuclear Medicine Test \ Mayada AbazarSulimanElmakki ; Mohamed Elfadil Mohamed .- Khartoum:Sudan University of Science & Technology,College of Medical Radiologic Science,2021.-63 p.:ill.;28cm.-M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/26476-
dc.descriptionThesisen_US
dc.description.abstractEstimate of effective dose for pediatric in Khartoum state for three nuclear medicine scan the thyroid, Kidney (dynamic renal scan with DTPA) and bone using descriptive, analytic and cross sectional method in the research. the average of effective dose to all patients according to their age, for age group from 1-3 years old the mean for thyroid was 1.2 mSv, for dynamic renal scan 0.73 mSv and for bone scan it was 3.45 mSv. For age group 4-8 years old the mean for thyroid was 2.84 mSv, for dynamic renal scan 0.80 mSv and for bone scan it was 3.32 mSv. For age group 9-13 years old the mean for thyroid was 2.22 mSv, for dynamic renal scan 0.82 mSv and for bone scan it was 3.35 mSv. For age group 14-17 years old the mean for thyroid was 1.85 mSv, for dynamic renal scan 0.76 mSv and for bone scan it was 3.45 mSv. And the comparison between present study with other studies according to ED where for thyroid the present study was 2.03 mSv while in ARPANSA 2008 study it was 2.2 mSv which consider higher than our present study. For dynamic renal scan present study was 0.78 mSv while in ARPANSA 2008 study was 6 mSv which consider higher than our present study while in Silvia Maria 2014 study was 0.75 mSv which consider lower than our present study. For bone present study was 3.39 mSv while in ARPANSA 2008 study was 5.5 mSv which consider higher than our present study.en_US
dc.description.sponsorshipSudan University of Science & Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectMedical Radiologic Sciencesen_US
dc.subjectNuclear Medicine Sciencesen_US
dc.subjectPediatric Patient’s Radiationen_US
dc.titleEstimation of Pediatric Patient’s Radiation Dose During Nuclear Medicine Testen_US
dc.title.alternativeتقييم الجرعة الاشعاعية للأطفال المرضى أثناء فحوصات الطب النوويen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Estimation of Pediatric ....pdfResearch779.62 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.