Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/26446
Title: Evaluation of RadiationDose during CT Brain
Other Titles: تقویم الجرعه الاشعاعیهاثناء التصویر المقطعي للدماغ
Authors: Mohammed, Hassan Alfadil Hassan
Supervisor, -Hussein Ahmed Hassan
Keywords: Medical Radiologic Sciences
Medical Physics
Evaluation of Radiation
Dose during CT Brain
Issue Date: 17-Mar-2021
Publisher: Sudan University of Science and Technology
Citation: Mohammed, Hassan Alfadil Hassan . Evaluation of RadiationDose during CT Brain \ Hassan Alfadil Hassan Mohammed ; Hussein Ahmed Hassan .- Khartoum:Sudan University of Science & Technology,College of Medical Radiologic Science,2021.-50 p.:ill.;28cm.-M.Sc.
Abstract: The purpose of this study was to Evaluate patient radiation doses of CT scanner during brain CT scan by calculate effective dose . In the study A sample of 100 adults patient their undergoing brain CT examinations were selected from different hospitals ( Yastabsheroon hospital and Asia hospital ) The data was taken during (2020) ,The machines were used namely : Toshiba 16 slice and GE Optima 16 slice. The results show amount of average effective dose (1.745 mSv ± 0.567 mSv ) and it's not equal or above than standard effective dose of brain (2 mSv) that recommended by ICRP . Also there is no any difference between effective dose of male brain and female brain according to differences at anatomical structure of brain .The typical parameter of (Kvp and mAs ) is (Kvp120) and (mAs60 -100 mAs) for adult and pediatric . The study recommends that the training is very important to all computed tomography technicians due to the high dose that result from CT.
Description: Thesis
URI: http://repository.sustech.edu/handle/123456789/26446
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Evaluation of Radiation....pdfResearch1.25 MBAdobe PDFView/Open