Please use this identifier to cite or link to this item:
https://repository.sustech.edu/handle/123456789/26446
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Mohammed, Hassan Alfadil Hassan | - |
dc.contributor.author | Supervisor, -Hussein Ahmed Hassan | - |
dc.date.accessioned | 2021-08-19T08:10:52Z | - |
dc.date.available | 2021-08-19T08:10:52Z | - |
dc.date.issued | 2021-03-17 | - |
dc.identifier.citation | Mohammed, Hassan Alfadil Hassan . Evaluation of RadiationDose during CT Brain \ Hassan Alfadil Hassan Mohammed ; Hussein Ahmed Hassan .- Khartoum:Sudan University of Science & Technology,College of Medical Radiologic Science,2021.-50 p.:ill.;28cm.-M.Sc. | en_US |
dc.identifier.uri | http://repository.sustech.edu/handle/123456789/26446 | - |
dc.description | Thesis | en_US |
dc.description.abstract | The purpose of this study was to Evaluate patient radiation doses of CT scanner during brain CT scan by calculate effective dose . In the study A sample of 100 adults patient their undergoing brain CT examinations were selected from different hospitals ( Yastabsheroon hospital and Asia hospital ) The data was taken during (2020) ,The machines were used namely : Toshiba 16 slice and GE Optima 16 slice. The results show amount of average effective dose (1.745 mSv ± 0.567 mSv ) and it's not equal or above than standard effective dose of brain (2 mSv) that recommended by ICRP . Also there is no any difference between effective dose of male brain and female brain according to differences at anatomical structure of brain .The typical parameter of (Kvp and mAs ) is (Kvp120) and (mAs60 -100 mAs) for adult and pediatric . The study recommends that the training is very important to all computed tomography technicians due to the high dose that result from CT. | en_US |
dc.description.sponsorship | Sudan University of Science & Technology | en_US |
dc.language.iso | en | en_US |
dc.publisher | Sudan University of Science and Technology | en_US |
dc.subject | Medical Radiologic Sciences | en_US |
dc.subject | Medical Physics | en_US |
dc.subject | Evaluation of Radiation | en_US |
dc.subject | Dose during CT Brain | en_US |
dc.title | Evaluation of RadiationDose during CT Brain | en_US |
dc.title.alternative | تقویم الجرعه الاشعاعیهاثناء التصویر المقطعي للدماغ | en_US |
dc.type | Thesis | en_US |
Appears in Collections: | Masters Dissertations : Medical Radiologic Science |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Evaluation of Radiation....pdf | Research | 1.25 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.