Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/25115
Title: Estimation of Effective Radiation Dose for chest during Computed Tomography Examinations
Other Titles: تقدير الجرعة الإشعاعية للصدر اثناء تصوير بالأشعة المقطعية
Authors: Bongi, Abdulrahman Bakhit Fadul
Supervisor, -Hussein A. Hassan
Keywords: Medical Radiologic Sciences
Effective Radiation Dose
Medical physics
chest during Computed Tomography Examinations
Issue Date: 11-Feb-2020
Publisher: Sudan University of Science and Technology
Citation: Bongi, Abdulrahman Bakhit Fadul . Estimation of Effective Radiation Dose for chest during Computed Tomography Examinations \ Abdulrahman Bakhit Fadul Bongi ; Hussein A. Hassan .- Khartoum:Sudan University of Science and Technology,College of Medical Radiologic Science,2020 .- 54 p.:ill.;28cm.-M.Sc.
Abstract: Computed Tomography is one of the most accurate and faster tool to diagnose diseases of the brain, chest, abdomen, and pelvis, And provides medical information that is different from other imaging examinations but delivers high radiation dose to patient. So calculation of patient dose is extremely important In the study A sample of 60 adults patients their undergoing chest CT examinations were selected from different centers (AL Police Hospital-khartoum Hospital, AL Faisal Hospital and Modern Medical Center) to estimate the quantity of effective dose for chest during computed tomography examination. The machines were used namely: Neusoft 16 slice,Toshiba 16 slice and GE Optima 16 slice. The results obtained the mean effective dose in three centers were (13.74-5.21-7.24) mSv respectively, as such the mean CDTIVOL was (26.85,11.64 and 10.7) mGy for Center A, B and C respectively, while the mean DLP in three centers was (981.14, 517.13, and 371.94) mGy.cm respectively. The study showed wide variations of patients doses in different centers, so Awareness of ALARA Principles is very important when performing CT examinations.
Description: Thesis
URI: http://repository.sustech.edu/handle/123456789/25115
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Estimation of Effective .....pdf
  Restricted Access
Research570.46 kBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.