dc.identifier.citation | Bongi, Abdulrahman Bakhit Fadul . Estimation of Effective Radiation Dose for chest during Computed Tomography Examinations \ Abdulrahman Bakhit Fadul Bongi ; Hussein A. Hassan .- Khartoum:Sudan University of Science and Technology,College of Medical Radiologic Science,2020 .- 54 p.:ill.;28cm.-M.Sc. | en_US |
dc.identifier.uri | http://repository.sustech.edu/handle/123456789/25115 | - |
dc.description | Thesis | en_US |
dc.description.abstract | Computed Tomography is one of the most accurate and faster tool to diagnose diseases of the brain, chest, abdomen, and pelvis, And provides medical information that is different from other imaging examinations but delivers high radiation dose to patient. So calculation of patient dose is extremely important In the study A sample of 60 adults patients their undergoing chest CT examinations were selected from different centers (AL Police Hospital-khartoum Hospital, AL Faisal Hospital and Modern Medical Center) to estimate the quantity of effective dose for chest during computed tomography examination. The machines were used namely: Neusoft 16 slice,Toshiba 16 slice and GE Optima 16 slice. The results obtained the mean effective dose in three centers were (13.74-5.21-7.24) mSv respectively, as such the mean CDTIVOL was (26.85,11.64 and 10.7) mGy for Center A, B and C respectively, while the mean DLP in three centers was (981.14, 517.13, and 371.94) mGy.cm respectively. The study showed wide variations of patients doses in different centers, so Awareness of ALARA Principles is very important when performing CT examinations. | en_US |
dc.description.sponsorship | Sudan University of Science & Technology | en_US |
dc.language.iso | en | en_US |
dc.publisher | Sudan University of Science and Technology | en_US |
dc.subject | Medical Radiologic Sciences | en_US |
dc.subject | Effective Radiation Dose | en_US |
dc.subject | Medical physics | en_US |
dc.subject | chest during Computed Tomography Examinations | en_US |
dc.title | Estimation of Effective Radiation Dose for chest during Computed Tomography Examinations | en_US |
dc.title.alternative | تقدير الجرعة الإشعاعية للصدر اثناء تصوير بالأشعة المقطعية | en_US |
dc.type | Thesis | en_US |
Appears in Collections: | Masters Dissertations : Medical Radiologic Science |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Estimation of Effective .....pdf Restricted Access | Research | 570.46 kB | Adobe PDF | View/Open Request a copy |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.