Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/23587
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAbdalla, Manahil Amir Mohamed-
dc.contributor.authorSupervisor, -Hussein Ahmad Hassan-
dc.date.accessioned2019-10-23T08:50:06Z-
dc.date.available2019-10-23T08:50:06Z-
dc.date.issued2019-07-24-
dc.identifier.citationAbdalla, Manahil Amir Mohamed . Evaluation of Patient Effective Dose and Organ Dose during Chest Computed Tomography \.Manahil Amir Mohamed Abdalla ; Hussein Ahmad Hassan .- Khartoum : Sudan University of Science and Technology , College of Medical Radiologic Science , 2019.- 72p. :ill;28cm.- M.Scen_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/23587-
dc.descriptionThesisen_US
dc.description.abstractThe aim of this study to evaluate of patient effective dose and radiation doses received by critical organs of the patients undergoing chest CT examination. The study was done on 61 patients (31 males and 30 females) in age range between 16 to 90 years , who came for routine chest multi-detector computed tomography model Toshiba Aquilition (16 slice) and CT Toshiba Alixon (16 slice) in two hospitals, in Khartoum state, namely (Alzaytouna and Yasatpshoron), during the period from September 2018 to February 2019. The parameters collected of the data (KVP, mAS, age, gender, slice thickness, total scan time, pitch, scan length, CTDIvol, and DLP), and calculated CTDIvol, DLP, E, and organ doses by CT expo version 2.5 software and the data were analyzed using Excel. The results of this study were the means of critical organ dose for hospital (Y) which were (12.8± 0.04)mSv, (12.4± 0.1) mSv, (6.7 ± 4.6) mSv for Breast, Lung, Thyroid respectively, and the means of critical organ dose for hospital (Z) were (27.8 ± 0.04) mSv, (27.2 ± 0.1) mSv, (38.8± 2.9) mSv, Breast, Lung, Thyroid respectively. The means of effective dose in hospital (Y) and hospital (Z) were (5.3 ± 1.04) mSv, (14.2 ± 1.8) mSv respectively. From which it could be conclude the radiation dose received by the critical organs of the patients undergoing CT chest examination at hospital (Z) is higher than radiation dose received by the critical organs of the patients undergoing CT chest examination at hospital (Y), and the mean of effective dose for patients at hospital (Z) is higher than the mean of effective dose for patients at hospital (Y). The effective dose in this study was compared with different reported values from Tanzania, Taiwan, United Kingdom, and EC reference and it was the lowest effective dose.en_US
dc.description.sponsorshipSudan University of Science & Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectMedical Radiologic Sciencesen_US
dc.subjectMedical Physicsen_US
dc.subjectPatient Effective Doseen_US
dc.subjectOrgan Dose during Chest Computed Tomographyen_US
dc.titleEvaluation of Patient Effective Dose and Organ Dose during Chest Computed Tomographyen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Evaluation of Patient ... .pdfResearch1.84 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.