SUST Repository

Estimation of Effective Dose of Gonads During Abdominal Scan using Computed Tomography

Show simple item record

dc.contributor.author Eltayeb, Osman Ibrahim Mohammed
dc.contributor.author Supervisor, -Eltayeb Wagiallh Eltayeb Wagiallh
dc.date.accessioned 2023-02-27T08:15:46Z
dc.date.available 2023-02-27T08:15:46Z
dc.date.issued 2022-05-26
dc.identifier.citation Eltayeb, Osman Ibrahim Mohammed . Estimation of Effective Dose of Gonads During Abdominal Scan using Computed Tomography \ Osman Ibrahim Mohammed Eltayeb ; Eltayeb Wagiallh Eltayeb Wagiallh .- Khartoum:Sudan University of Science & Technology,College of Medical Radiologic Science,2022.-51p.:ill.;28cm.-M.Sc. en_US
dc.identifier.uri https://repository.sustech.edu/handle/123456789/28176
dc.description Thesis en_US
dc.description.abstract This descriptive, cross sectional study aimed to estimate the effective dose of gonads in abdominal multi-detector helical computed tomography examinations. The problem of the study was that there is no recent local study that estimates effective dose for 3gonads; the most recent one was before four years ago. The study was done in 140 patients (72 males and 68 females) in range of age between 16 to 90 years old, who came for enhanced abdominal multi-detector computed tomography (one to five runs), during the period from April2022 to august 2022, in hospitals and diagnostic centers in Khartoum state include (Omer.Sawi.Medical Hospital, Alfisa.hospital, Doctors hospital, AL Nileien.medical Diagnostic Center and AL Zytoona specialized hospital). The data was collected and analyzed by statistical package for social sciences.The study shows the highest effective dose was in 64 slices scanner (278.0077msv), that because of using inappropriate protocol for abdomen exams. On other hand lower dose (84.2730 msv) in 128 slices scanner. The statistical table showed different manufacture with same number of slice (16 slices) Toshiba was higher dose(248.0443msv) than Canon (138.0829msv) according to independent t test ( p=0.00) which indicate significant difference between manufacture. Comparing with previous studies we found that CTDI volume of our study (43 mGy) was higher than local and international previous studies (5.4 mGy and 35.6 mGy) respectively. Comparing the present study with the national and international organization and diagnostic reference level worldwide; our present study found the DLP(2105.9mGy.cm) was higher than the international studies(1200 mGy.cm) in Germany and Australia and also higher than the study conducted in Sudan (459 mGy.cm)(2010) On the other hand the effective dose of the present study was higher than all national and international studies. The study recommends that appropriate selection of technical parameters that reduce radiation dose without affecting image quality must be take in place. en_US
dc.description.sponsorship Sudan University of Science & Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science & Technology en_US
dc.subject Medical Radiologic Sciences en_US
dc.subject Diagnostical Technology en_US
dc.subject Effective Dose en_US
dc.subject Gonads During Abdominal Scan en_US
dc.subject Computed Tomography en_US
dc.title Estimation of Effective Dose of Gonads During Abdominal Scan using Computed Tomography en_US
dc.title.alternative تقدير الجرعة الفعالة للأعضاء التناسلية أثناء التصوير بالاشعة المقطعية المحوسبة للبطن en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record