SUST Repository

Assessment of Plasma Uric Acid Level and Blood Urea Nitrogen/Creatinine Ratio in Preeclamptic Sudanese Women at Khartoum state

Show simple item record

dc.contributor.author Mohamed, Maazza Omer Adam
dc.contributor.author Supervisor, - Abdelgadir Ali Elmugadam
dc.date.accessioned 2023-02-19T10:24:58Z
dc.date.available 2023-02-19T10:24:58Z
dc.date.issued 2022-09-01
dc.identifier.citation Mohamed, Maazza Omer Adam.Assessment of Plasma Uric Acid Level and Blood Urea Nitrogen/Creatinine Ratio in Preeclamptic Sudanese Women at Khartoum state\Maazza Omer Adam Mohamed;Abdelgadir Ali Elmugadam.-Khartoum:Sudan University of Science & Technology,College of Medical Laboratory Science,2022.-60p.:ill.;28cm.-M.Sc. en_US
dc.identifier.uri https://repository.sustech.edu/handle/123456789/28122
dc.description Thesis en_US
dc.description.abstract Preeclampsia is a pregnancy related syndrome; it is one of hypertensive disorders of pregnancy, associated with different organ involvement, marked by new onset hypertension and proteinurea. This is case control study aimed to assess uric acid level and blood urea nitrogen creatinine ratio in preeclamptic Sudanese women in period of time between March to June 2022. One hundred thirty pregnant ladies included, (80) were diagnosed with preeclampsia and (50) were non preeclamptic normal pregnant ladies, levels of uric acid, urea and creatinine were measured, blood urea nitrogen and blood urea nitrogen creatinine ratio were calculated, statistical analysis for data was done using statistical package of social science (SPSS) software program version 20. Results show significant increase in uric acid level among preeclamptic (7.11±2.08 mg/dl) compared to normal pregnant group (3.65 ± 1.06 mg/dl) with P. value (0.000). Levels of urea, creatinine and blood urea nitrogen were significantly increased in the preeclamptic comparing to the normal pregnant P. value (0.001, 0,022 and 0.001) respectively, yet their values still within normal limit. Blood urea nitrogen creatinine ratio showed insignificant increase in the preeclampsia group (14.92 ± 5.56) compared to non preeclamptic normal group (12.91 ± 7.32) with P. value (0.099), There is insignificant correlation between age of the preeclamptic women and uric acid nor age and blood urea nitrogen creatinie ratio. The study conclude that: plasma uric acid increase in preeclampsia independent to the age effect, study also found the blood urea nitrogen creatinine ratio is within normal range in preeclampsia. en_US
dc.description.sponsorship Sudan University of Science & Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science & Technology en_US
dc.subject Uric Acid Level en_US
dc.subject Blood Urea Nitrogen en_US
dc.subject Creatinine Ratio en_US
dc.title Assessment of Plasma Uric Acid Level and Blood Urea Nitrogen/Creatinine Ratio in Preeclamptic Sudanese Women at Khartoum state en_US
dc.title.alternative تقييم مستويات حمض البوليك و نسبة نيتروجين البولينا في الدم الي الكرياتنين في بلازما النساء السودانيات المصابات بمتلازمة ماقبل تسمم الحمل بولاية الخرطوم en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Share

Search SUST


Browse

My Account