Increasing the Heat Transfer Efficiency of Heating System by the AdjustingFlow Rate of Thermanol/ Crude Oil

Show simple item record

dc.contributor.author Ahmed, Ismail Ahmed Ismail
dc.contributor.author Supervisor, -Abdlla Mokhtar MohammedAbdlla
dc.date.accessioned 2021-07-25T12:15:58Z
dc.date.available 2021-07-25T12:15:58Z
dc.date.issued 2020-10-22
dc.identifier.citation Ahmed, Ismail Ahmed Ismail . Increasing the Heat Transfer Efficiency of Heating System by the AdjustingFlow Rate of Thermanol/ Crude Oil : Petrodar Pipeline Case Study \ Ismail Ahmed Ismail Ahmed ; Abdlla Mokhtar MohammedAbdlla .- Khartoum: Sudan University of Science and Technology, college of Engineering and Petroleum Technology, 2020. -62p. : ill. ;28cm .- M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/26349
dc.description Thesis en_US
dc.description.abstract The aim of the research is to identify the maximum efficiency of the heating system and investigate the opportunities of operating cost reduction the inPetrodaroperation company pipeline crude by adjusting thermal oil flow rate, real data (readings) such as temperature, of flow rate taken, analyzed and put into tables and graphs and calculating system efficiencywith corresponding thermail oil by excel program. The data taken for five months starting from October 2017 untilFebruary 2018.The maximum thermal efficiencywas 90.73% with lower fuel consumption 5 cubic meters per hour in December 2017, when the thermal oil flow rate (thermanol) was670315kg/ h. The appropriate fuel consumption 5 cubic meter per hours which is gives the highest crude oil temperature about 71.9 ° C. By using the finding result, we can consider it as a reference operating condition for the heating system en_US
dc.description.sponsorship Sudan University of Science and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Petroleum Engineering & Technology en_US
dc.subject Petrodar Pipeline en_US
dc.subject Heat Transfer Efficiency en_US
dc.subject AdjustingFlow Rate en_US
dc.subject Crude Oil en_US
dc.title Increasing the Heat Transfer Efficiency of Heating System by the AdjustingFlow Rate of Thermanol/ Crude Oil en_US
dc.title.alternative رفع كفاءة انتقال الحرارهلمنظومة التسخين من خلال ضبط معدل تدفق زيت التسخينللنفط الخام en_US
dc.type Thesis en_US