SUST Repository

Evaluation of Glucose Level in Serum and Plasma Using Different Anticoagulants at Room Temperature

Show simple item record

dc.contributor.author Fathalbab, Sara Hassan Mohammed
dc.contributor.author Supervisor, - Seifeldeen Ahmed Mohamed Elragouba
dc.date.accessioned 2021-01-20T11:27:05Z
dc.date.available 2021-01-20T11:27:05Z
dc.date.issued 2020-10-01
dc.identifier.citation Fathalbab, Sara Hassan Mohammed.Evaluation of Glucose Level in Serum and Plasma Using Different Anticoagulants at Room Temperature\Sara Hassan Mohammed Fathalbab;Seifeldeen Ahmed Mohamed Elragouba.-Khartoum:Sudan University of Science & Technology,College of Medical Laboratory Science,2020.-44p.:ill.;28cm.-M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/25645
dc.description Thesis en_US
dc.description.abstract Back ground: Glucose is key to keeping the mechanisms of the body in top working order. Along with fats, glucose is one of the body's preferred sources of fuel. Glucose levels that are unhealthy or out of control can have permanent and serious effects. Objective: To measure blood glucose level storage in different anticoagulants at room temperature. Methodology: The study was conducted in Khartoum state from the period of March to September 2020. Including 60 healthy volunteers age range between 20 to 60 years old. The blood samples were dispended into different containers (fluoride oxalate, sodium citrate, lithium heparin and plain container). The glucose level was measured initially (at zero time) after 2, 4, 6 and 8 hours in the plasma and serum using colorimetric method (glucose oxides) then the data obtained were analyzed using (SPSS) in computer program. Results: The result show that the stability of blood glucose level in fluoride oxalate up to 4 hours (P-value ≥ 0.005) while in heparin and sodium citrate and serum up to 2 hours (P-value ≥ 0.005). Conclusion: From the result it was conclude that fluoride oxalate is more suitable anticoagulant for blood glucose estimation. en_US
dc.description.sponsorship Sudan University of Science @ Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science & Technology en_US
dc.subject Glucose Level en_US
dc.subject Serum and Plasma en_US
dc.subject Anticoagulants en_US
dc.title Evaluation of Glucose Level in Serum and Plasma Using Different Anticoagulants at Room Temperature en_US
dc.title.alternative تقويم مستوي سكر الجلكوز في مصل وبلازما الدم باستخدام موانع تجلط مختلفة في درجة حرارة الغرفة en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Share

Search SUST


Browse

My Account