SUST Repository

Estimation of Effective Radiation Dose for chest during Computed Tomography Examinations

Show simple item record

dc.contributor.author Bongi, Abdulrahman Bakhit Fadul
dc.contributor.author Supervisor, -Hussein A. Hassan
dc.date.accessioned 2020-10-12T07:44:55Z
dc.date.available 2020-10-12T07:44:55Z
dc.date.issued 2020-02-11
dc.identifier.citation Bongi, Abdulrahman Bakhit Fadul . Estimation of Effective Radiation Dose for chest during Computed Tomography Examinations \ Abdulrahman Bakhit Fadul Bongi ; Hussein A. Hassan .- Khartoum:Sudan University of Science and Technology,College of Medical Radiologic Science,2020 .- 54 p.:ill.;28cm.-M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/25115
dc.description Thesis en_US
dc.description.abstract Computed Tomography is one of the most accurate and faster tool to diagnose diseases of the brain, chest, abdomen, and pelvis, And provides medical information that is different from other imaging examinations but delivers high radiation dose to patient. So calculation of patient dose is extremely important In the study A sample of 60 adults patients their undergoing chest CT examinations were selected from different centers (AL Police Hospital-khartoum Hospital, AL Faisal Hospital and Modern Medical Center) to estimate the quantity of effective dose for chest during computed tomography examination. The machines were used namely: Neusoft 16 slice,Toshiba 16 slice and GE Optima 16 slice. The results obtained the mean effective dose in three centers were (13.74-5.21-7.24) mSv respectively, as such the mean CDTIVOL was (26.85,11.64 and 10.7) mGy for Center A, B and C respectively, while the mean DLP in three centers was (981.14, 517.13, and 371.94) mGy.cm respectively. The study showed wide variations of patients doses in different centers, so Awareness of ALARA Principles is very important when performing CT examinations. en_US
dc.description.sponsorship Sudan University of Science & Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Medical Radiologic Sciences en_US
dc.subject Effective Radiation Dose en_US
dc.subject Medical physics en_US
dc.subject chest during Computed Tomography Examinations en_US
dc.title Estimation of Effective Radiation Dose for chest during Computed Tomography Examinations en_US
dc.title.alternative تقدير الجرعة الإشعاعية للصدر اثناء تصوير بالأشعة المقطعية en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Share

Search SUST


Browse

My Account