SUST Repository

EVALUATION OF PELVIMETRIC RADIOGRAPHS QUALITY IN A REPRODUCTIVE HEALTH CARE CENTER

Show simple item record

dc.contributor.author Mustafa, Sahar Abd Elwahed Osman Mustafa
dc.contributor.author Supervisor -Hussein Ahmed Hassan
dc.date.accessioned 2013-11-13T09:58:05Z
dc.date.available 2013-11-13T09:58:05Z
dc.date.issued 2011-05-01
dc.identifier.citation Mustafa,Sahar Abd Elwahed Osman Mustafa. EVALUATION OF PELVIMETRIC RADIOGRAPHS QUALITY IN A REPRODUCTIVE HEALTH CARE CENTER/Sahar Abd Elwahed Osman MustafaMustafa;Hussein Ahmed Hassan.- Khartoum : sudan university of science and technology,Medical radiologic Science,2011.- 80p . ill : ;28cm .-M.sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/2256
dc.description Thesis en_US
dc.description.abstract This study is about evaluation of the pelvimetric image quality by conventional x-ray to primary gravid ladies. To assess the female pelvic in relation of bipartetal diameter of baby head to decide the normal vaginal delivery possible or commence cesarean section. This study included sampling of 23 primary gravid ladies to detect the the role of examination. The study was conducted in 2011 in the reproductive health care center in Khartoum city. The researcher collected the data of the pelvimetric examination from pregnant ladies and then analyzed and discussed the results. The researcher concluded that, the radiation dose in the center exceeded the normal range, and in the measurement of inlet the more frequency was found 15cm with 58.8% and in outlet more frequency was found 14cm with 58.8% from total sampling (17 pregnant ladies). And in the head of the baby was found the more frequency was 11cm with 82.4% from total sampling (17 pregnant ladies). In quality of image the more frequency was found v. good image with 65.52% from total sampling (23 images of pelvimetry). From all, the researcher recommended to use high kv technique to reduce the radiation dose to patient, and selected the technical factor related to the patient weight, highest, and used the collimation to avoid unnecessary radiation dose to the patient. en_US
dc.description.sponsorship sudan university of science and technology en_US
dc.language.iso en en_US
dc.publisher sudan university of science and technology en_US
dc.subject EVALUATION en_US
dc.subject RADIOGRAPHS en_US
dc.title EVALUATION OF PELVIMETRIC RADIOGRAPHS QUALITY IN A REPRODUCTIVE HEALTH CARE CENTER en_US
dc.type Thesis en_US