SUST Repository

Optimization of Radiation Dose in Multislices CT scan Examinations

Show simple item record

dc.contributor.author Elmahdi, Ali Mohamed Abdelrazig
dc.date.accessioned 2013-11-12T11:54:09Z
dc.date.available 2013-11-12T11:54:09Z
dc.date.issued 2011-11-01
dc.identifier.citation Elmahdi,Ali Mohamed Abdelrazig .Optimization of Radiation Dose in Multislices CT scan Examinations /Ali Mohamed Abdelrazig Elmahdi;Abdelmoneim Adam Mohamed Sulieman.- Khartoum : sudan university of science and technology,Mediscal RadiologicScience,2011.-89p. : ill ;28cm.- M.sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/2219
dc.description Thesis en_US
dc.description.abstract Computed Tomography (CT) is a diagnostic imaging modality giving higher patient dose in comparison with other radiological procedures, so the calculation of patient dose in CT exams is very important. CT improved the diagnosis many of the diseases. The increasing use of CT in the Sudan in recent years is what has to think in the attempt to reduce the exposure of the patient and that the risks known to the X-ray. This study aimed to measure the radiation dose and estimating the risks resulting from exposure to X-rays during the imaging by CT scan. A total of 130 patients were examined in two hospitals using two spiral CT scans 64 slices (Alamal National and Alzaytouna specialist hospitals in the period (March 2011-June 2011). The average age of the samples was 45±18 years. The mean effective dose for Al-amal National hospital was 17.4±12.7 mSv, 22.9±14.3 mSv and 2.4±0.9 mSv for the chest, abdomen and brain examinations, respectively. The mean effective doses for Al-Zaytouna specialist hospital were 26.3±7.8 mSv, 47.6±33.0 mSv, and 3.7±1.5 mSv for the chest, abdomen and brain, respectively. The dose of this study is relatively higher compared to previous studies locally and internationally. This can be attributed to lack of training in CT dose optimisation and CT modality. The study showed the urgent need to review and evaluation of dose and also the need for continuous training of workers in this field and establishing the diagnostic reference level in the Sudan. en_US
dc.description.sponsorship sudan university of science and technology en_US
dc.language.iso en en_US
dc.publisher sudan university of science and technology en_US
dc.subject Optimization en_US
dc.subject Radiation en_US
dc.title Optimization of Radiation Dose in Multislices CT scan Examinations en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Share

Search SUST


Browse

My Account