SUST Repository

Estimation of patient's radiation diagnostic doses in nuclear medicine

Show simple item record

dc.contributor.author Mubarak, Riham Gamal Eldeen Adam
dc.date.accessioned 2017-04-05T14:17:36Z
dc.date.available 2017-04-05T14:17:36Z
dc.date.issued 2016-10-01
dc.identifier.citation Mubarak, Riham Gamal Eldeen Adam. Estimation of patient's radiation diagnostic doses in nuclear medicine\ Riham Gamal Eldeen Adam Mubarak. - Khartoum: Sudan University for Science and Technology, College of Science, 2016.- 44p. :ill ;28cm .- Bachelor Search en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/16018
dc.description Bachelor Search en_US
dc.description.abstract This study intends to estimate the patients radiation diagnostic doses in nuclear medicine. A total of 60 patients were examined in two Hospitals. The data were collected using a sheet for all patients in order to maintain consistency of the information. The following parameters were recorded age, weight and height to estimate the dose for thyroid scan, renal scan and bone scan. The examinations were collected according to the availability. The mean age, weight and height are 77.37, 66.76 and 1.64 respectively for male in elneelian center.The mean age, weight and height are 59.70, 67.86 and 1.61 respectively for female in elneelain center. The mean age, weight and height are 70.17, 69.34 and 1.62 respectively for male in elmek nimer hospital. The mean age, weight and height are 51.33, 62.40 and 1.68 respectively for female in elmek nimer hospital The mean doses of thyroid, renal and bone scan are 5.04, 9.19 and 20.10 respectively in elneelain center. The mean doses of thyroid, renal and bone scan are 5.24, 8.05 and 22.10 respectively in elmek nimer hospital. Patient doses were measuring during this study used on two hospitals to three types of organ diagnosed. demographic data (age, weight, height, sex, clinical indication, and type of organ diagnosed) were meausured. Dose calibrator were used to measure organ doses. Two different gamma camera machines were used throughout this study. In this study bone scan doses values were higher than the other two types of diagnosed while thyroid scan diagnosed is lowest one. en_US
dc.description.sponsorship Sudan University for Science and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University for Science and Technology en_US
dc.subject laboratories- Physics en_US
dc.subject nuclear medicine en_US
dc.subject Estimation of patient's en_US
dc.title Estimation of patient's radiation diagnostic doses in nuclear medicine en_US
dc.title.alternative تقييم الجرعة الاشعاعية التشخيصية للمرضى ف الطب النووي en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Share

Search SUST


Browse

My Account