SUST Repository

Effectt of Compensating Filter on Image Quality in Lateral projection of Thoracolumbar Radiography

Show simple item record

dc.contributor.author Ahmed, EsraaJaafarElamin
dc.contributor.author Supervisor,- Ahmed Mostafa Abukonna
dc.date.accessioned 2016-03-07T06:07:00Z
dc.date.available 2016-03-07T06:07:00Z
dc.date.issued 2016-01-04
dc.identifier.citation Ahmed,EsraaJaafarElamin.Effectt of Compensating Filter on Image Quality in Lateral projection of Thoracolumbar Radiography\ EsraaJaafarElamin Ahmed; Ahmed Mostafa Abukonna .- Khartoum:Sudan University of Science and Technology,College Radiologic Sciences,2016.-58p:ill;28cm.-M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/12896
dc.description Thesis en_US
dc.description.abstract Imaging of the thoracolumbar area is difficult because of different composition and density in that region. The difference may cause non uniformity of optical density on radiograph. The aim of this research was to study the effect of compensating filter on image quality in lateral projection of thoracolumbar radiography. The study was performed by an X-ray unit exposed to the body phantom where different thicknesses of aluminum were used as compensating filter. The radiographs were processed by DICOM reader and being imported to KPACS software to analyze the pixel depth value, contrast and noise. it was found that the compensation filter increased radiographic image quality for thoracic lumber region by compensate the radiation energy that reach the thoracic region and appears dark without the filter and the lumber region which are low dense and shows good quality image and acceptable in image diagnosis without the filter. It was also found that the appropriate filter thickness was 8 mm in the thoracic region and 2mm in the lumber region and Thickness of Aluminum compensating filter required to compensate the thorax and lumbar region was 5 mm. Finally, the addition of aluminum compensating filter is advantageous in terms of efficiency which saving radiograph film, workload of the radiologic technologist and radiation dose to patient. en_US
dc.description.sponsorship Sudan University of Sciences and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science & Technology en_US
dc.subject Effectt of Compensating en_US
dc.subject Radiography en_US
dc.subject Radiologic Sciences en_US
dc.subject Lateral projection en_US
dc.title Effectt of Compensating Filter on Image Quality in Lateral projection of Thoracolumbar Radiography en_US
dc.title.alternative تأثیر المرشح التعویضي في جودة الصورة الجانبیة في تصویر الفقرات الصدریة و القطنیة en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Share

Search SUST


Browse

My Account