SUST Repository

Determination of Prothrombin time and International Normalized Ratio by Using Manual and Semi automated Methods in Khartoum Teaching Hospital Laboratory

Show simple item record

dc.contributor.author Alkhalifa, Samia Mahjoub Elhassan
dc.contributor.author Supervisor, - Babiker Mohammed Ahmed
dc.date.accessioned 2016-02-29T09:47:49Z
dc.date.available 2016-02-29T09:47:49Z
dc.date.issued 2015-12-01
dc.identifier.citation Alkhalifa, Samia Mahjoub Elhassan.Determination of Prothrombin time and International Normalized Ratio by Using Manual and Semi automated Methods in Khartoum Teaching Hospital Laboratory/Samia Mahjoub Elhassan Alkhalifa;Babiker Mohammed Ahmed.-Khartoum:Sudan University of Science & Technology,Medical Laboratory Science,2015.-71p.:ill.;28cm.-M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/12859
dc.description Thesis en_US
dc.description.abstract This is descriptivecross sectionalstudy carried out in the Khartoum teaching hospital research and laboratory unit to determine the Prothrombin time and International normalized ratio. The Prothrombin time and International normalized ratio was measured in100 blood samples.4.5ml of venous blood was drown from each patients placed in tri sodium citrate containers then centrifugated to get platelet poor plasma. PT measured by the manual method and semi automated method (DiagnosticaStago). The aim of this study to compare the reliability of prothrombin test using manual and semi-automated method coagulation analyzer. Results were analyzed by Statistical package for social science average ±SD and P.value was obtained. It has been found that there was no significant variation between PT and INR values when using the manual and semi automated with P.value (≥0.05). The result for the prothrombin time test obtained by semi automated is reliable and is statistically equivilant to those obtained by the manual method. The study concluded that there weretwo methods gave the same results indicating good calibrated machine. en_US
dc.description.sponsorship Sudan University of Science and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science & Technology en_US
dc.subject Prothrombin time en_US
dc.subject International Normalized Ratio en_US
dc.subject automated Methods en_US
dc.title Determination of Prothrombin time and International Normalized Ratio by Using Manual and Semi automated Methods in Khartoum Teaching Hospital Laboratory en_US
dc.title.alternative تحدید زمن البروثرومبین ونسبة الضبط العالمیة بإستخدام الطریقة الیدویة وشبه الأتوماتیكیة بمعمل مستشفى الخرطوم التعلیمي en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record