SUST Repository

Measurement of the Esophageal Motion in External Beam Irradiation

Show simple item record

dc.contributor.author Elteep, Motwakil Elsiddig
dc.contributor.author Supervisor,- Yousif Mohamed Yousif Abdallah
dc.date.accessioned 2015-06-30T07:56:36Z
dc.date.available 2015-06-30T07:56:36Z
dc.date.issued 2015-02-01
dc.identifier.citation Elteep, Motwakil Elsiddig. Measurement of the Esophageal Motion in External Beam Irradiation/ Motwakil Elsiddig Elteep; Yousif Mohamed Yousif Abdallah.- khartoum: Sudan University of Science and Technology, College of Medical Radiologic Science, 2015.- 36p. : ill. ; 28cm.- M. Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/11216
dc.description Thesis en_US
dc.description.abstract This study aimed to measure the shift of esophagus motion in external beam irradiation which lead to increase accuracy of determination of both PTV and ITV resulting in increase and enhancing therapeutic ratio and minimizing toxicity of both neighboring structure and rest volume of esophagus . This study was collected when treated patient is simulated using CT simulator of esophagus and chest organ treatment of cancer where the respiratory gated, three dimensional CT imaging of the full expiratory motion and minimum and maximum displacement was measured based in CT data. The data analyzed with Mat lab program under windows with t-test to assess the Motion of Esophagus in Radiation Therapy, The final result show that there was a difference in average between the oesophagus position regarding to (X-reading) of the inspiration phase which is equal to 10.16 + 3.31 and 10.6 +3.02. This difference was not significant at p= .05 using t-test with t= -9.74 and p=0.001. As well as here is a difference in average between the oesophagus position regarding to (Y-reading) of the inspiration phase which is equal to 8.6 + 2.02 and 12.7 +1.12. This difference was significant using t-test with t= .162 and p=0.87 en_US
dc.description.sponsorship Sudan University of Science and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Radiologic Science en_US
dc.subject Beam Irradiation en_US
dc.subject Measurement of the Esophageal en_US
dc.subject الحركة في الخارجية شعاع en_US
dc.title Measurement of the Esophageal Motion in External Beam Irradiation en_US
dc.title.alternative ‫قياس حركة المرئ في التشعيع بالحزمة من‬ الخارج en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Share

Search SUST


Browse

My Account