SUST Repository

Evaluation of CT brain protocols, image

Show simple item record

dc.contributor.author Ali, Umaima Saad Elamin
dc.contributor.author Supervisor - Husain Ahmed Hasan
dc.date.accessioned 2015-02-05T11:29:42Z
dc.date.available 2015-02-05T11:29:42Z
dc.date.issued 2014-01-01
dc.identifier.citation Ali,Umaima Saad Elamin .Evaluation of CT brain protocols, image :Umaima Saad Elamin Ali;.Husain Ahmed Hasan .-khartuom:Sudan University of science & Technology,College of Medical Radiologic Science,2014.-129p.;ill.;28cm.-M Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/10314
dc.description Thesis en_US
dc.description.abstract CT scan is one of the most valuable tools used in the centers of modern health care and are accompanied by radiation dose greater than that of the normal radiographic and must be therefore use carefully to protect patients from radiation. The aim of this study to compare between radiation dose and image quality and to compare between CT brain protocols and radiation dose . Random samples consist of 30 patients who underwent CT brain examination. The patients data registered(age, gender, exposure factors(kv, mAs, exposure time, slice thickness, No of slices) and the DLP, CTDI. where the distribution of the patients was 13 women and 17 male, ages from 6 months to 70 years. The study group has been taken from Modern medical center, Alzaytouna specialist hospital and the Advanced diagnostic center, samples of the population from Khartoum - Sudan. Study was conducted in the period from October 2013 to February 2014 where the study showed that the radiation dose generally increase with intensity of the current, exposure time, the thickness of the slice and the number of slices, also study showed that the image quality increases with radiation dose, However the study showed there is an existence of images with good to very good in quality in less radiation dose . The artifacts generally increases as the exposure time increase and has a close association with movement of the patient. where the study showed that the radiation dose generally increase with mAs, scan time, slice thickness and the number of slices and showed that the image quality increases with radiation dose, However there is an existence of 20% of mages having acceptable, good and very good in quality when we reduce the radiation dose to the half . Also The study showed that artifacts generally increases as the exposure time increases and has a close association with movement of the patient. en_US
dc.description.sponsorship Sudan University for science and technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of science & Technology en_US
dc.subject College of Radiology en_US
dc.subject Medical physics en_US
dc.subject Evaluation of CT brain protocols en_US
dc.subject , image quality and radiation dose en_US
dc.title Evaluation of CT brain protocols, image en_US
dc.title.alternative تقويم جودة الصورة والجرعة الأشعاعية في بروتوكولات التصوير المقطعي للدماغ en_US
dc.type Thesis en_US