dc.contributor.author |
Mustafa, Badria Awad El Amin |
|
dc.contributor.author |
Supervisor-Husain Ahmed Hassan |
|
dc.date.accessioned |
2015-02-04T07:30:04Z |
|
dc.date.available |
2015-02-04T07:30:04Z |
|
dc.date.issued |
2005-08-01 |
|
dc.identifier.citation |
Mustafa,Badria Awad El Amin .survey of routine brain ct protocols in khartoum state:Badria Awad El Amin Mustafa;Husain Ahmed Hassan.-khartuom:Sudan University of Science and Technology,College of Medical Radiologic Science,2005.-193p.:ill;28cm.-M. Sc. |
en_US |
dc.identifier.uri |
http://repository.sustech.edu/handle/123456789/10281 |
|
dc.description |
Thesis |
en_US |
dc.description.abstract |
This survey study is performed to determine the variations in
routine brain CT protocols in all centers in Sudan, because the
choice of scanning protocol in CT will affect the dose delivered to
the patients and quality of the image. The types and characteristics
of CT scanners have major role in type of protocol and will
influence radiation dose to the patients.
This research follows both descriptive and analytical
methods. Special questionnaire for the technologists was designed
to collect information about protocols of brain CT. This
questionnaire contains the following technical issues: -
radiographic baseline, slice thickness / slice spaces, exposure
factors and doses of contrast media used in each department.
Data was collected from patients referred to the CT scan
departments in duration of two weeks (from Saturday 16/4 to
VI
Saturday 30/4/2005). They were (800) patients from different
states, ages, male and female having different pathologies. (560)
patients were undergoing brain CT scans with 70 % from the
total number.
The researcher found that:-
1- The protocols of brain CT scan shows wide variations in many
technical aspects. For example:- radiographic baseline, slice
thickness / slice spaces, exposure factors used by the operators
and different doses of contrast media used in the departments.
2- 22 % of the departments under study used for adults, S.O.M.
baseline and thus avoided scanning the lenses of eyes, and for
children, only 33 % of the departments using this baseline.
3- In all centers under study, the routine protocols do not include
scans after injection of contrast media, unless there is an
indication.
4- In using slice thickness / slice spaces for example, using of
10/10 mm slice thickness / slice spaces for adults was 22 % from
the departments and 45 % for the children using this slice
thickness / slice spaces.
5- All centers using low doses of contrast media which will affect
the degree of lesion enhancement, may lead to mis-diagnosis |
en_US |
dc.description.sponsorship |
Sudan University of Science and
Technology |
en_US |
dc.language.iso |
en |
en_US |
dc.publisher |
Sudan University of Science and Technology |
en_US |
dc.subject |
Radiologic |
en_US |
dc.subject |
Diagnostic Radiologic Technology |
en_US |
dc.subject |
survey of routine brain ct |
en_US |
dc.subject |
protocols khartuom state |
en_US |
dc.title |
survey of routine brain ct protocols in khartoum state |
en_US |
dc.type |
Thesis |
en_US |