Abstract:
Mammography is a valuable tool in the early detection of breast cancer,
the American College of Radiology’s (ACR) Breast Imaging Reporting
and Data System (BI-RADS) provide a lexicon that give a standard way
of reporting mammogram that help constant reporting and ensure better
follow up of benign and suspicious findings.
The research conduct to assess the concordance of final findings of
mammograms reported using BI-RADS lexicons and the final impression
of radiologist those using routine interpretation of mammogram. The
research was retrospective study design, and included 300
mammographic image for women aged between 15 to 90 years old, the
mammograms obtained by digital mammography machine and used the
basic mammographic projections (CC: Craniocaudal and MLO:
Mediolateral Oblique).The data descriptively analyzed and measured the
different variables in the research and determined the relationship
between them, Kappa value was determined to measure the concordance.
Regarding to age, the most abundant group was (46-60 years) as
(40%).Regarding to Breast composition, the most abundant group was
scattered fibroglandular breast (b) group for both routine interpretation
and BIRAD.The result appeared as the concordance of the breast
composition was (k = 0.5) that point Moderate agreement. All
pathological findings were founded and the concordance among the
descriptive terms measured, According to Mass, the presence of the mass
was (k = 0.83) that was a Very Good agreement, the shape of the mass
was (k = 0.53) that a Moderate agreement, the margin of the mass was (k
= 0.475) that point Moderate agreement, the density of the mass was (k =
0.74) that point a good agreement, in addition the associate calcifications
was (k = 1) that point a total agreement. According to Calcification the
IV
Kappa value was for presence (k = 0.87) that point to Very Good
agreement, the morphology of the calcifications was (k = 0.85) that point
to Very Good agreement and distribution was (k = 1) that point Very
Good agreement. In addition, the Architectural distortion was (k =
0.85) that point to Very Good agreement, and A symmetry was (k = 1.3)
it was poor agreement. The intramammary lymph node was (k = 0.65)
that point a good agreement and the overall agreement and concordance
to the Final finding (BIRAD Categories) was (k = 0.58) that point to a
moderate agreement. The research found a significant relationship
between the different variables such as breast composition with age as (Pvalue
= 0.000), final findings with age(P-value = 0.000), mass presence (Pvalue
= 0.000), mass shape (P-value = 0.000), mass margin (P-value = 0.000),
mass density (P-value = 0.000), mass associated calcification (P-value =
0.000), mass location (P-value = 0.000), presence of calcification (P-value =
0.000), architectural distortion (P-value = 0.001), presence of asymmetry (Pvalue
= 0.000), presence of inflammatory lymph node (P-value = 0.000),
presence of associated features (P-value = 0.000) and presence of solitary
dilated duct as (P-value = 0.000).
As the conclusion to the research, there is a moderateagreement with
radiologist when reporting mammogram, which mean some variation in
wording of the mammography report between the radiologists. Therefore,
it is very importance to the similarity wording of the mammography
report to avoid any misunderstanding or confusion, and following of
BIRAD lexicon leads to this goal.