Please use this identifier to cite or link to this item:
https://repository.sustech.edu/handle/123456789/9566
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Osman, Hiba Ali | |
dc.contributor.author | Hassan, Sana Yahia | |
dc.contributor.author | Fawzi, Demiana Edward | |
dc.contributor.author | Ahmed, Sulafa Basher | |
dc.contributor.author | Supervisor - MOHAMED ELFADIL GARELNABI | |
dc.contributor.author | Supervisor - MOHAMED ELFADIL GARELNABI | |
dc.date.accessioned | 2015-01-06T09:07:33Z | |
dc.date.available | 2015-01-06T09:07:33Z | |
dc.date.issued | 2014-08-01 | |
dc.identifier.citation | Osman,Hiba Ali;Optimization of Lumbosacral X-Ray Exposure Factors/Hiba Ali Osman...{etal};MOHAMED ELFADIL GARELNABI-.Khartoum : Sudan University of Science & Technology ,College of Medical Radiologic Science,2014.-50 P:ill;28 cm.-Bachelors search. | en_US |
dc.identifier.uri | http://repository.sustech.edu/handle/123456789/9566 | |
dc.description | Search Bachelor | en_US |
dc.description.abstract | This research discusses the parameters that affected the optimization of exposure factors of lumbosacral region. This research found that most important parameter is weight and it is a significant one and can affected in to selection of exposure factors of lumbosacral region regardless if the patients male or female and the selection of exposure factors of AP and Lateral lumbosacral region don't influence by patients age and length. This research found a number of equations that can be give the patients the appropriate dose for imaging of lumbosacral region instead of guessing according to consideration of the patient or using of the exposure chart. This equations proportion only with the weight, according to it can select the optimize exposure factors for lumbosacral region. The study consisted of 40 patients, their mean age, height; weight was 39.2±13.8, 166±7.9, 67.2±14.3 respectively. While the average exposure factors for AP concerning the KV and mAs was 80.5±10.3, 36.9±10.3 respectively. and the average exposure factor for lateral projection concern KV and mAs was 87.4±5.1 , 44.1±7. | en_US |
dc.description.sponsorship | Sudan University of Science and Technology | en_US |
dc.language.iso | en | en_US |
dc.publisher | Sudan University of Science and Technology | en_US |
dc.subject | Lumbosacral | en_US |
dc.subject | X-Ray Exposure | en_US |
dc.title | Optimization of Lumbosacral X-Ray Exposure Factors | en_US |
dc.title.alternative | أمثلة عوامل التصوير للفقرات القطنية العجزية | en_US |
dc.type | Thesis | en_US |
Appears in Collections: | Bachelor of Medical Radiologic Science |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Optimization of Lumbosacral....pdf | Title | 125.21 kB | Adobe PDF | View/Open |
Abstract.pdf | Abstract | 174.43 kB | Adobe PDF | View/Open |
Chapter one.pdf | Research | 2.23 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.