Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/9566
Full metadata record
DC FieldValueLanguage
dc.contributor.authorOsman, Hiba Ali
dc.contributor.authorHassan, Sana Yahia
dc.contributor.authorFawzi, Demiana Edward
dc.contributor.authorAhmed, Sulafa Basher
dc.contributor.authorSupervisor - MOHAMED ELFADIL GARELNABI
dc.contributor.authorSupervisor - MOHAMED ELFADIL GARELNABI
dc.date.accessioned2015-01-06T09:07:33Z
dc.date.available2015-01-06T09:07:33Z
dc.date.issued2014-08-01
dc.identifier.citationOsman,Hiba Ali;Optimization of Lumbosacral X-Ray Exposure Factors/Hiba Ali Osman...{etal};MOHAMED ELFADIL GARELNABI-.Khartoum : Sudan University of Science & Technology ,College of Medical Radiologic Science,2014.-50 P:ill;28 cm.-Bachelors search.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/9566
dc.descriptionSearch Bacheloren_US
dc.description.abstractThis research discusses the parameters that affected the optimization of exposure factors of lumbosacral region. This research found that most important parameter is weight and it is a significant one and can affected in to selection of exposure factors of lumbosacral region regardless if the patients male or female and the selection of exposure factors of AP and Lateral lumbosacral region don't influence by patients age and length. This research found a number of equations that can be give the patients the appropriate dose for imaging of lumbosacral region instead of guessing according to consideration of the patient or using of the exposure chart. This equations proportion only with the weight, according to it can select the optimize exposure factors for lumbosacral region. The study consisted of 40 patients, their mean age, height; weight was 39.2±13.8, 166±7.9, 67.2±14.3 respectively. While the average exposure factors for AP concerning the KV and mAs was 80.5±10.3, 36.9±10.3 respectively. and the average exposure factor for lateral projection concern KV and mAs was 87.4±5.1 , 44.1±7.en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectLumbosacralen_US
dc.subjectX-Ray Exposureen_US
dc.titleOptimization of Lumbosacral X-Ray Exposure Factorsen_US
dc.title.alternativeأمثلة عوامل التصوير للفقرات القطنية العجزيةen_US
dc.typeThesisen_US
Appears in Collections:Bachelor of Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Optimization of Lumbosacral....pdfTitle125.21 kBAdobe PDFView/Open
Abstract.pdfAbstract174.43 kBAdobe PDFView/Open
Chapter one.pdfResearch2.23 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.