dc.identifier.citationIBRAHIM ,MOHAMED AHMED ABDALLA ELHAG.Effect of the Inter-cooler on Gas Turbine Performance/MOHAMED AHMED ABDALLA ELHAG IBRAHIM ;Ali Mohammed Hamdan Adam.-khartoum:Sudan University of Science and Technology,College of Engineering,2014.-61p:ill;28cm.-M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/9042
dc.descriptionthesisen_US
dc.description.abstractIn this research, a cycle model of a gas turbine power plant with the effect of intercooler along with a detailed parametric study. The effects of parameter on the power output, compression work, specific fuel consumption and thermal efficiency are evaluated. The study shows that, the implementation of inter-cooling increases the power generating efficiency. Inter cooler gas turbine cycle is analyzed. Different effected parameters are simulated, including different compressor pressure ratios, different ambient temperature; air fuel ratio and turbine inlet temperature, were analyzed. The obtained results are presented and analyzed. Further increasing the cyclepeak temperature ratio and total pressure ratio can still improve the performance of the intercooled gas turbine cycle.en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectMECHANICAL ENGINEERINGen_US
dc.subjectThe effect of coolant interfaceen_US
dc.subjectPerformance gas turbineen_US
dc.titleEffect of the Inter-cooler on Gas Turbine Performanceen_US
dc.title.alternativeتأثير المبرد البيني على أداء التوربينة الغازيةen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Engineering

Files in This Item:
File Description SizeFormat 
Effect of the Inter-cooler ....pdftitle319.34 kBAdobe PDFView/Open
Abstract.pdfAbstract345.44 kBAdobe PDFView/Open
Chapter 1.pdfChapter 173.71 kBAdobe PDFView/Open
Chapter 2.pdfChapter 159.57 kBAdobe PDFView/Open
Chapter 3.pdfChapter 467.94 kBAdobe PDFView/Open
Chapter 4.pdfChapter 372.2 kBAdobe PDFView/Open
Chapter 5.pdfChapter 330.01 kBAdobe PDFView/Open
Chapter 6.pdfChapter 146.66 kBAdobe PDFView/Open
References.pdfReferences150.96 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.