dc.identifier.citationMohammed,Hytham Ahmed. Transient Performance of Synchronous Generators Boosted by a bank of Capacitor:Degree of Science in Electrical Power/Hytham Ahmed Mohammed;Yousif Hassan A. Rahim.-khartuom:Sudan University of Science and Technology,College of Engineering,2004.-63p:ill;28cm.-M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/8435
dc.descriptionthesisen_US
dc.description.abstractIn this research the transient performance of synchronous generator boosted by a bank of capacitor and connected to infinite bus bar through transformer and feeder has been studied. The system is represented by using mathematical model based on Park's transformation. In this research the optimum value of the machine parameters have been deduced by using optimization algorithm method. In this research we found that higher level of boosting gives more damping torque during disturbance. So by using Fast Fourier Transform (FFT) analyze we found that higher level of boosting reduces the amplitude of a.c. components of armature current, load current and capacitor current during disturbance. In addition we deduced that increasing of MVA causes decreasing of critical fault clearing time (CFCT). The main conclusion of this thesis is to improve the behavior of synchronous generator during disturbance by connecting a bank of capacitors across the terminals of generator.en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectTransient Performanceen_US
dc.subjectSynchronous Generatorsen_US
dc.subjectElectrical Engineeringen_US
dc.titleTransient Performance of Synchronous Generators Boosted by a bank of Capacitoren_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Engineering

Files in This Item:
File Description SizeFormat 
Transient Performance of Synchronous .. .pdftitle75.17 kBAdobe PDFView/Open
CONTENTS .pdfCONTENTS 34.85 kBAdobe PDFView/Open
CHAPTER ONE.pdf
  Restricted Access
CHAPTER 68.47 kBAdobe PDFView/Open Request a copy
CHAPTER two.pdf
  Restricted Access
CHAPTER 70.56 kBAdobe PDFView/Open Request a copy
CHAPTER THREE.pdf
  Restricted Access
CHAPTER 2.88 MBAdobe PDFView/Open Request a copy
CHAPTER Four.pdf
  Restricted Access
CHAPTER 350.93 kBAdobe PDFView/Open Request a copy
CHAPTER FIVE.pdfCHAPTER 41.96 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.