Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/8294
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGomah, Gamal Ebrahim
dc.contributor.authorSupervisor - Sabir Mohammed Salih
dc.date.accessioned2014-11-27T12:55:33Z
dc.date.available2014-11-27T12:55:33Z
dc.date.issued2010-02-01
dc.identifier.citationGomah , Gamal Ebrahim .Effect of Ambient Air Temperature on the Performance Factor of a Combined Cycle in Garri Power Plant/Gamal Ebrahim Gomah;Sabir Mohammed Salih.-Kartoum:Sudan University of Science and Technology,College of Engineering,2010.-87P. : ill. ; 28Cm.-M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/8294
dc.descriptionThesisen_US
dc.description.abstractThe Combined cycle (Gas/Steam) Performance is highly sensitive to the Ambient Air temperature. Sudan is one of the countries which have high ambient air temperature and low humidity. As a result, power output from combined cycle decreases and the specific fuel consumption increases. When there is high power demand needed especially during summer season and the high price of fuel (light diesel oil).This problems can be avoided by cooling compressor inlet air temperature. By application of media cooling system (evaporative) in Garri Combined cycle. The ambient air temperature decreased 38% for Gt7 & 31% for Gt8. The performance test result show that the Compressor Specific work decreased by 1.15% for Gt7 & 2.9% for Gt8, Specific Net work increased by 1.15% for Gt7 & 2.9 for Gt8, power output increased by 11% for Gt7 & 8.8% for Gt8, Specific fuel consumption decreased by 1.8% for Gt7 & 3.3% for Gt8, Fuel saving equal 0.22% forGt7 & 0.29% for Gt8, Gas turbine Efficiency increased by 0.62% for Gt7 & 0.92% for Gt8, Exhaust flow rate increased by 7.9%, Steam turbine pressure increased by 4.5%, Steam turbine power output increased by 2.2%, and Combined cycle Efficiency increased by 0.06%.en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectMechanical Engineeringen_US
dc.subjectAir Temperatureen_US
dc.subjectCombined Cycleen_US
dc.subjectGarri Power Planten_US
dc.titleEffect of Ambient Air Temperature on the Performance Factor of a Combined Cycle in Garri Power Planten_US
dc.title.alternativeتأثير درجة حرارة الجو فى معامل أداء الدورة المزدوجة فى محطة كهرباء قرى للتوليدen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Engineering

Files in This Item:
File Description SizeFormat 
Effect of Ambient Air Temperature ... .pdftitle62.86 kBAdobe PDFView/Open
Research.pdf
  Restricted Access
Research799.1 kBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.