Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/8281
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAbd-Allah, Mohammed Mohy-Eldeen
dc.contributor.authorSupervisor - Yousif Ali Yousif
dc.date.accessioned2014-11-27T09:22:06Z
dc.date.available2014-11-27T09:22:06Z
dc.date.issued2009-08-01
dc.identifier.citationAbd-Allah,Mohammed Mohy-Eldeen .Evaluation of Fire Protection Systems in Buildings/Mohammed Mohy-Eldeen Abd-Allah;Yousif Ali Yousif.-Kartoum:Sudan University of Science and Technology,Engineering,2091.-92P. : ill. ; 28Cm.-M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/8281
dc.descriptionThesisen_US
dc.description.abstractThe general objective of this research is to study and evaluate the fire protection systems used in the National Telecom Corporation (N.T.C) Tower in Khartoum town. The specific objectives include the study of different systems used in the N.T.C building for fire protection and the building design and to compare them with the National Standards. Also the research aims to recommend suitable solutions needed and prepare a modular document to be applied by designers for similar buildings in Sudan. The methodology followed to achieve this research includes the information taken from the specific references, experts (National fire Protection Association NFPA and British standard BS), specialized companies in the field, site visits and the civil defense authority, also the careful study of the project and making comparison between the project safety requirement applied and the International Codes such as the National fire Protection Association NFPA ( which is approved by civil defense in Sudan ) and with the British standards . The case study results include that the N.T.C. building is designed architecturally and structurally according to the NFPA code. Also the fire alarm and protection systems of the N.T.C. building, and the public addressable system, access control and evacuation plan are well designed and satisfied standards according to the NFPA code standards. The study recommends that the building should be provided with clear signs to improve the access control in the last floor to guide people for the escape landing area. Also a stair case in suitable place with short distance after last staircase flight . Also the stair-cases hand rails should be increased in height for more safety, or fixing horizontal net (in the U shape staircase) for safety because the crowdness of people in case of incident will be dangerous. Also it is recommended that fire design must be considered as part of the overall building design of the structure and not an item to be considered at the end. And the insurance companies should provide their services for fire incidents after achieving the fire safety requirements by civil defense authority certification , in addition to training of personnel in this field ,.. etc.en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectCivil Engineeringen_US
dc.subjectBuilding Servicesen_US
dc.subjectFire Protection Systemsen_US
dc.subjectFireen_US
dc.subjectational Telecom Corporation Toweren_US
dc.titleEvaluation of Fire Protection Systems in Buildingsen_US
dc.title.alternativeتقويم أنظمة الحماية من الحريق بالمبانى : دراسة حالة برج الهيئة العامة للإتصالاتen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Engineering

Files in This Item:
File Description SizeFormat 
Evaluation of Fire Protection.pdftitle103.18 kBAdobe PDFView/Open
Abstract.pdfAbstract122.27 kBAdobe PDFView/Open
Research.pdf
  Restricted Access
Research259.33 kBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.