Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/7955
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMolan, Mahdi Akram
dc.contributor.authorSupervisor - Mohamed Ahmed El-Siraj
dc.date.accessioned2014-11-11T12:29:04Z
dc.date.available2014-11-11T12:29:04Z
dc.date.issued2005-09-10
dc.identifier.citationMolan, Mahdi Akram. Cooling System And Condenser Problems In Dr. Shareef Power Station: The Thesis Submitted In Partial Fulfillment Of The Requirement For The Master Degree Of Science In Power Engineering. / Mahdi Akram Molan;Mohamed Ahmed El-Siraj.-khartuom:Sudan University of Science and Technology, College of Engineering. ,2005.-141p:ill;28cm.-M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/7955
dc.descriptionthesisen_US
dc.description.abstractThis research deals with the energy resource in Sudan. It included the steam plants, their components problems. The study is applied on Dr. Shareef Power Station in Khartoum North. It studied and displayed the station cooling system problems and the hazards which occur to this station; the deterioration of its performance and to the periods of its redundancy. The findings of the research show that the deterioration of performance of the condenser, is due to the following: 1.Cooling tower problems. 2.Condenser problems. 3.Bad quality cooling water. 4.The non-conducting of the specified tests of the cooling water. 5.Problems of the other components of the cooling system. Several suggestions were proposed for the maintenance; so as to avoid the occurrence of the current problems. This would help in increase of the efficiency of the stations. Likewise, Proposal was provided for doing that.en_US
dc.description.sponsorshipSudan University of Science And Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectCooling Systemen_US
dc.subjectCondenser Problemsen_US
dc.subjectShareef Power Stationen_US
dc.titleCooling System And Condenser Problems In Dr. Shareef Power Stationen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Engineering

Files in This Item:
File Description SizeFormat 
cooling system .pdftitle105.73 kBAdobe PDFView/Open
chapter 1.pdf
  Restricted Access
chapter 113.31 kBAdobe PDFView/Open Request a copy
chapter 2.pdf
  Restricted Access
chapter 1.83 MBAdobe PDFView/Open Request a copy
Chapter 3.pdf
  Restricted Access
chapter 1.52 MBAdobe PDFView/Open Request a copy
Chapter 4.pdf
  Restricted Access
chapter 2.2 MBAdobe PDFView/Open Request a copy
Chapter 5.pdf
  Restricted Access
chapter 577.13 kBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.