dc.identifier.citationSalim,Abbas Abdelazem Hassabalrasol.Evaluation of the performance of evaporative coolers using Luffa pads (Direct Evaporation)/Abbas Abdelazem Hassabalrasol Salim;Yousif Hassan Mohammed Ali.-Khartoum :Sudan University Of Science And Technology,College of Engineering,2013 .-34P:ill;28Cm.-M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/7701
dc.descriptionThesisen_US
dc.description.abstractHigh energy demand associated to the massive use of air conditioning systems requires careful consideration of passive cooling strategies, with evaporative cooling being recognized as a useful possibility for that purpose. One important factor that influences the performance of evaporative cooling systems is the media material that supports water evaporation process (cooling pad). As a result a lot of research is being carried out to determine the performance of the cooling pads experimentally. The major purpose of the study was to evaluate the performances of using Luffa (local natural fibers Type) to be used as wetted pads in direct evaporative cooling. The tests were carried out at two levels of air velocity (4 m/s and 8 m/s) and two levels of pad thickness (40 mm and 80 mm). According to the results of this study, it can be stated that the average maximum saturation efficiency is highest for Luffa at 95.1%, compared to 90% for the reference commercial pad. The results show that there are a negative relationship between the cooling efficiency and the air velocity and a positive one with the pad thickness change.en_US
dc.description.sponsorshipSudan University of Science &Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science &Technologyen_US
dc.subjectHigh energy demand associated to the massive use of air conditioning systems requires careful consideration of passive cooling strategies, with evaporative cooling being recognized as a useful possibility for that purpose. One important factor that influences the performance of evaporative cooling systems is the media material that supports water evaporation process (cooling pad). As a result a lot of research is being carried out to determine the performance of the cooling pads experimentally. The major purpose of the study was to evaluate the performances of using Luffa (local natural fibers Type) to be used as wetted pads in direct evaporative cooling. The tests were carried out at two levels of air velocity (4 m/s and 8 m/s) and two levels of pad thickness (40 mm and 80 mm). According to the results of this study, it can be stated that the average maximum saturation efficiency is highest for Luffa at 95.1%, compared to 90% for the reference commercial pad. The results show that there are a negative relationship between the cooling efficiency and the air velocity and a positive one with the pad thickness change.en_US
dc.subjectMECHANICALen_US
dc.titleEvaluation of the performance of evaporative coolers using Luffa pads (Direct Evaporation)en_US
dc.title.alternativeتقويم أداء المبردات التبخيرية بإستخذام وسائد الليف التبخير المباشرen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Engineering

Files in This Item:
File Description SizeFormat 
Evaluation of the performance of evaporative .pdftitle146.12 kBAdobe PDFView/Open
ABSTRACT.pdfABSTRACT578.44 kBAdobe PDFView/Open
chapter one.pdf
  Restricted Access
chapter 328.38 kBAdobe PDFView/Open Request a copy
chaper two.pdf
  Restricted Access
chapter 777.99 kBAdobe PDFView/Open Request a copy
chaper three.pdf
  Restricted Access
chapter 678.99 kBAdobe PDFView/Open Request a copy
chaper four.pdf
  Restricted Access
chapter 439.81 kBAdobe PDFView/Open Request a copy
chaper five.pdf
  Restricted Access
chapter 314.26 kBAdobe PDFView/Open Request a copy
References.pdfReference318.94 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.