dc.identifier.citationEBU ELHASSAN,ELKHATIM MOHAMED AHMED.REMOVING OCULAR ARTIFACTS FROM EEG RECORDING USING AN ADAPTIVE FILTERIING AND WAVELET TRANSFORM/ELKHATIM MOHAMED AHMED EBU ELHASSAN;OMER E. H. HAMID .-Khartoum: Sudan University of Science and Technology, College of Engineering, 2011.-58p :ill :28cm .-M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/4962
dc.descriptionThesisen_US
dc.description.abstractEye blinks and movements of the eyeballs produce electrical signals that are collectively known as Ocular Artifacts (OA) and these are 10-100 times stronger than EEG signal which is being recorded. Removing artifacts from EEG signal may aid the work of doctors, because artifacts disturb their attention. This research presents a new method to remove automatically ocular artifacts in contaminated EEG signals. The method is based on Recursive Least Square (RLS) Adaptive Filter through stationary wavelet transform (SWT). The stationary wavelet transform (SWT) is used as a pre-stage before the Recursive Least Square (RLS) Adaptive Filtering, to produce ocular artifact free EEG signal. The results show that, in some cases, the method is 20 times better when compared to the use of the traditional FFT method of removing ocular artifactsen_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectBiomedical Engineeringen_US
dc.subjectEEG RECORDINGen_US
dc.subjectADAPTIVE FILTERIINGen_US
dc.subjectWAVELET TRANSFORMen_US
dc.subjectOCULAR ARTIFACTSen_US
dc.titleREMOVING OCULAR ARTIFACTS FROM EEG RECORDING USING AN ADAPTIVE FILTERIING AND WAVELET TRANSFORMen_US
dc.title.alternativeإزالة التشويش الناتج من حركة العين أثناء تخطيط كهربائية المخ باستخدام الترشيح التكيُفي وتحويل المويجاتen_US
dc.typeThesisen_US
dc.contributor.SupervisorSupervisor ,- OMER E. H. HAMID
Appears in Collections:Masters Dissertations : Engineering

Files in This Item:
File Description SizeFormat 
REMOVING OCULAR ARTIFACTS ...pdftitle44.83 kBAdobe PDFView/Open
ABSTRACT.pdfABSTRACT60.09 kBAdobe PDFView/Open
Research ..pdf
  Restricted Access
Research 2.3 MBAdobe PDFView/Open Request a copy
Table 5.1.pdfTable 32.39 kBAdobe PDFView/Open
Table 5.2.pdfTable 32.69 kBAdobe PDFView/Open
Table 5.3.pdfTable 33.04 kBAdobe PDFView/Open
Table 5.4.pdfTable 32.95 kBAdobe PDFView/Open
Table 5.5.pdfTable 32.69 kBAdobe PDFView/Open
Table 5.6.pdfTable 32.83 kBAdobe PDFView/Open
Table 5.7.pdfTable 31.99 kBAdobe PDFView/Open
APPENDIX A.pdfAPPENDIX 32.58 kBAdobe PDFView/Open
APPENDIX A - 2.pdfAPPENDIX 26.77 kBAdobe PDFView/Open
APPENDIX A 1 - 3.pdfAPPENDIX 24.64 kBAdobe PDFView/Open
APPENDIX A - 4.pdfAPPENDIX 23.53 kBAdobe PDFView/Open
APPENDIX A - 5.pdfAPPENDIX 24.41 kBAdobe PDFView/Open
APPENDIX A - 6.pdfAPPENDIX 19.24 kBAdobe PDFView/Open
APPENDIX_B.pdfAPPENDIX 32.6 kBAdobe PDFView/Open
APPENDIX_C.pdfAPPENDIX 33.84 kBAdobe PDFView/Open
APPENDIX_D.pdfAPPENDIX 33.13 kBAdobe PDFView/Open
APPENDIX_E.pdfAPPENDIX 29.69 kBAdobe PDFView/Open
APPENDIX_H.pdfAPPENDIX 30.17 kBAdobe PDFView/Open
APPENDIX_I.pdfAPPENDIX 37.94 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.