dc.identifier.citationOmer,Alamin Musa Salih . Evaluation of Quality Control Protocols for Computed Tomography Scanners in Khartoum Centers/Alamin Musa Salih Omer;Mamdouh Yassin Osman .- Khartoum : sudan university of science and technology,Medical Radiologic science , 2007. -70p . : ill . ;28cm . M. sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/4335
dc.descriptionThesisen_US
dc.description.abstractQuality control (QC) in any activity refers to the routine and special procedures developed to ensure that the final product is of consistently high quality. Quality control in diagnostic radiology requires a planed, continuous program of evaluation and surveillance of radiologic equipment and procedures. The main purpose of this study is to assess the performance of some of CT scanners used for radiodiagnosis and to evaluate the quality control program in Khartoum State Computed Tomography (CT) centers. The main parameters monitored and tested during the QC program include, average CT number of water, field uniformity, noise, lower contrast resolution, high contrast resolution, slice thickness, bed indexing, couch travel accuracy, light field accuracy, contrast scale and linearity. The total tested CT machines were 7 out of 10. All of the tested scanners passed the following tests field uniformity, noise characteristics, bed index, high contrast resolution, light field accuracy, slice thickness, couch travel accuracy, contrast scale and linearity. However - for some of these scanners - deviations of the results from the standard values have reached the maximum tolerance and this indicates that those machines are in bad need for preventive maintenance. The percentage of success for other tests were 57.1%, and 50% for the average CT number of water, and low contrast resolution test respectively. The study showed also that there is no QA program performed regularly in most of the CT centers involved in this study, such program includes - among others - QC tests, calibration, staff training, preventive maintenance and repair. In addition most of centre do not have the QC tools and depend on the service engineer in calibrating and testing of their machines. Finally the study showed that there is more efforts are needed to enforce the SAEC act that regulates the use of radiation in different applications including the medical field.en_US
dc.description.sponsorshipsudan university of science and tchnologyen_US
dc.language.isoenen_US
dc.publishersudan university of science and technologyen_US
dc.subjectEvaluationen_US
dc.subjectTomographyen_US
dc.titleEvaluation of Quality Control Protocols for Computed Tomography Scanners in Khartoum Centersen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Research.pdf
  Restricted Access
Research2.44 MBAdobe PDFView/Open Request a copy
Evaluation of Quality Control ... .pdfTitle117.74 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.