Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/4208
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAlameen, SuhaibMohamedsalihAhamed
dc.contributor.authorsupervisor -Elhussaien Hassan Ahamed
dc.date.accessioned2014-04-02T11:53:21Z
dc.date.available2014-04-02T11:53:21Z
dc.date.issued2013-07-01
dc.identifier.citationAlameen,SuhaibMohamedsalihAhamed.Evaluation of Image Quality and Radiation Dose in Computed Radiography/SuhaibMohamedsalihAhamedAlameen;Elhussaien Hassan Ahamed.-Khartoum : sudan university of science and technology,Medical Radiologic Science ,2013.-53p :ill . ; 28cm. .-M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/4208
dc.descriptionThesisen_US
dc.description.abstractIV Abstract The assessment of image quality and patient dose from computed radiography for common x-ray examinations namely skull Posterior Anterior and Lateral , chest Posterior Anterior , lumber spine Anterior Posterior and Lateral and pelvis Anterior Posterior radiography was perfumed in three private hospitals in capital Khartoum . image quality evaluated by using threshold contrast-detail phantom (TO. 20). Assessment obtained by average scores from four specialist . This study deals with evaluation of patient dose received by patients undergoing radiological examinations , Three large hospitals in Khartoum were selected and 164 patients made up the sample .The entrance surface doses (ESDs) to patient undertakening four common x.ray examination (skull PA& LAT , chest PA , lumber spine AP & LAT, pelvis AP) were estimated using ionization chamber for air kerma measurements . Exposure settings and patients data were recorded . Result concerning the kilovoltage (KVp) and tube current (mAs) and focus to film distance (FFD) settings . and the ESD values were analyzed and compared (by other hospitals) to those recommended by the EU . discrepancies in the patient doses and techniques used for the examinations studied were found among the different hospitals denoting the importance of establishing a national quality assurance programme and examination protocols to ensure patient doses are Kept as Low as possible . All the examinations studied fulfilled the EU recommendations . The result of image quality show small different between three hospitals which indicate the routine quality assurance and quality control play important role in the equipment performance.en_US
dc.description.sponsorshipsudan university of science and technologyen_US
dc.language.isoenen_US
dc.publishersudan university of science and technologyen_US
dc.subjectEvaluationen_US
dc.subjectRadiographyen_US
dc.titleEvaluation of Image Quality and Radiation Dose in Computed Radiographyen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Research .pdf
  Restricted Access
Research1.12 MBAdobe PDFView/Open Request a copy
Abstract .pdfAbstract 173.52 kBAdobe PDFView/Open
Evaluation of Image ... .pdf Title 103.34 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.