Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/4193
Full metadata record
DC FieldValueLanguage
dc.contributor.authorIbrahim, Islam Tag Alsir Abdullah
dc.contributor.authorsupervisor -Ikhlas Abdul-Aziz
dc.date.accessioned2014-04-02T08:06:39Z
dc.date.available2014-04-02T08:06:39Z
dc.date.issued2013-09-01
dc.identifier.citationIbrahim,Islam Tag Alsir Abdullah.Effect of AP diameter in patient dose during CT abdomen and chest /Islam Tag Alsir Abdullah Ibrahim;Ikhlas Abdul-Aziz.-Khartoum : sudan university of science and technology, Medical Radiologic Science.2013.-95p. : ill . ;28cm. M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/4193
dc.descriptionThesisen_US
dc.description.abstractComputed tomography (CT) is considered the main source of radiation exposure to general population. There is an increased CT usage owing to technological advancement. Multiple slice CT scanners produce better image quality with less scan time and more clinical applications quality which linked to higher radiation dose to patients. This study is to investigate the relationships among cross-sectional diameters, weight and computed tomography (CT) dose descriptors (CTDI and DLP) to identify which is best used as a measure for the establishment of DRLs in CT. The importance of using the AP diameter are that it can easily be measured prior to scanning or retrospectively from previous CT images. A total of 65 patients were examined in this study. The data was collected from the following examinations: Abdomen and chest from Al-Amal national hospital (50 patients for abdomen and 15 patients for chest). Also this study was to identify an optimal cross-sectional chest - abdomen diameter that correlates with image quality and radiation exposure in MDCT examinations of the chest- abdomen performed with automatic tube current modulation. To measure the effective dose (ED) we use the equation = DLP× convoluted factor and it calculate the mean and standard deviation for any sample and multiply the result with DLP if the dose increase with increase of DLP we conclude that there’s reduction in radiation which come to patienten_US
dc.description.sponsorshipsudan university of science and technologyen_US
dc.language.isoenen_US
dc.publishersudan university of science and technologyen_US
dc.subjectEffecten_US
dc.subjectduringen_US
dc.titleEffect of AP diameter in patient dose during CT abdomen and chest.en_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Effect of AP diameter ... .pdf
  Restricted Access
Research730.02 kBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.